检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Xiaolei Wang Yuanyuan Zhang Tingting Liu Chuan Song Xiaoyu Xue Jun Liu Hongxin Zhao
机构地区:[1]Clinical Center for HIV/AIDS,Beijing Ditan Hospital,Capital Medical University,Beijing,China [2]Beijing Institute of Infectious Diseases,Beijing,China [3]Beijing Key Laboratory of Emerging Infectious Diseases,Institute of Infectious Diseases,Beijing Ditan Hospital,Capital Medical University,Beijing,China [4]National Center for Infectious Diseases,Beijing Ditan Hospital,Capital Medical University,Beijing,China [5]Beijing Ditan Hospital,Peking University,Beijing,China [6]Department of Gynecology,Beijing Ditan Hospital,Capital Medical University,Beijing,China
出 处:《China CDC weekly》2024年第31期793-798,I0001,I0002,共8页中国疾病预防控制中心周报(英文)
摘 要:Introduction:The Nugent score,limited by subjectivity and personnel requirements,lacks accuracy.Establishing a precise and simple molecular test is therefore essential for detecting vaginal microbiota compositions and evaluating vaginal health.Methods:We evaluated the vaginal health of Chinese women using quantitative polymerase chain reaction(qPCR)to target Lactobacillus crispatus(L.crispatus),L.iners,Gardnerella vaginalis(G.vaginalis),Atopobium vaginae(A.vaginae),and Megasphaera phylotype1.bacterial vaginosis(BV)-related bacteria shared a fluorescent channel.Using 16S rDNA sequencing as a reference standard,we evaluated and validated the diagnostic accuracy of the qPCR assay.Results:Both qPCR and 16S rDNA sequencing demonstrated 90.5%concordance in segregating vaginal community state type(CST),as visualized through heatmaps and PCoA.Spearman’s correlation analysis revealed strong correlations between the two methods in calculating the RA of L.crispatus(CST I),L.iners(CST III),and BV-related bacteria(CST IV),with coefficients of 0.865,0.837,and 0.827,respectively.Receiver operating characteristic analysis showed that qPCR had significant diagnostic accuracy for CST I,CST III,and CST IV(molecular BV),with area under the curve values of 0.967,0.815,and 0.950,respectively,indicating strong predictive power.Discussions:Vaginal health can be evaluated using a single qPCR amplification experiment,making the multiplex qPCR assay a highly accurate tool for this purpose.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.133.149.244