检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:张林嘉 余小敏 林健 仇承恩 王铮先 ZHANG Linjia;YU Xiaomin;LIN Jian;CHOU Chengen;WANG Zhengxian(Key Laboratory of Biomedical Effect of Physical Field and Instrument,School of Electrical and Electronic Engineering,Chengdu University of Information Technology,Chengdu 610225,P.R.China;Chongqing Institute of Microelectronics and Microsystems,Beijing Institute of Techonology,Chongqing 401332,P.R.China;Sichuan Acad Medicine Science&Sichuan Province Peoples Hospital,Chengdu 610072,P.R.China)
机构地区:[1]成都信息工程大学电子工程学院物理场生物效应及仪器四川省高校重点实验室,成都610225 [2]北京理工大学重庆微电子研究院,重庆401332 [3]四川省医学科学院四川省人民医院,成都610072
出 处:《生物医学工程学杂志》2024年第4期818-825,共8页Journal of Biomedical Engineering
基 金:四川省科技计划重点研发项目(2023YFS0468)。
摘 要:基于光电检测的运动血氧饱和度(血氧)检测仪其性能在很大程度上受到光电容积脉搏波(PPG)信号中运动噪声的影响。本文提出一个针对运动血氧检测的算法,该算法通过完全自适应噪声集合经验模态分解联合多尺度排列熵构造运动噪声参考信号,并结合凸组合最小均方自适应滤波器消除PPG信号中的运动噪声,以计算动态血氧。测试结果表明,在模拟步行、慢跑状态下,本算法计算的血氧值与参考血氧值的平均绝对误差分别为0.05和0.07,平均绝对百分比误差分别为0.05%和0.07%,总体皮尔逊相关系数达到0.9712。实验结果证实,本文研究算法有效地降低了PPG信号中的运动伪影,有望应用于便携光电式脉搏血氧仪,以提高动态血氧测量的准确性。The performance of a pulse oximeter based on photoelectric detection is greatly affected by motion noise(MA)in the photoplethysmographic(PPG)signal.This paper presents an algorithm for detecting motion oxygen saturation,which reconstructs a motion noise reference signal using ensemble of complete adaptive noise and empirical mode decomposition combined with multi-scale permutation entropy,and eliminates MA in the PPG signal using a convex combination least mean square adaptive filters to calculate dynamic oxygen saturation.The test results show that,under simulated walking and jogging conditions,the mean absolute error(MAE)of oxygen saturation estimated by the proposed algorithm and the reference oxygen saturation are 0.05 and 0.07,respectively,with means absolute percentage error(MAPE)of 0.05%and 0.07%,respectively.The overall Pearson correlation coefficient reaches 0.9712.The proposed scheme effectively reduces motion artifacts in the corrupted PPG signal and is expected to be applied in portable photoelectric pulse oximeters to improve the accuracy of dynamic oxygen saturation measurement.
关 键 词:光电容积脉搏波 血氧饱和度 运动噪声 信号分解 噪声重构
分 类 号:TN29[电子电信—物理电子学] TN713[医药卫生—生物医学工程] R318[医药卫生—基础医学]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.222