Comparison of dynamic defocus curve Checkfor updates on cataract patients implanting extended depth of focus and monofocal intraocular  

在线阅读下载全文

作  者:Tingyi Wu Yuexin Wang jiazhi Yu Xiaotong Ren Yuanting Li Weigiang Qiu Xuemin Li 

机构地区:[1]Department of Ophthalmology,Peking University Third Hospital,49 North Garden Road,Haidian District,Beijing 100191,People's Republic of China [2]Bejing Key Laboratory of Restoration of Damaged Ocular Nerve,PekingUniversity Third Hospital,Beijing,People's Republic of China [3]Peking University Health Science Center,Beijing,People's Republicof China.

出  处:《Eye and Vision》2024年第4期32-40,共9页眼视光学杂志(英文)

基  金:This work was supported by Bejing Municipal Science and Technology Commission(Grant No.7202229);Peking University Medicine Fund of Fostering Young Scholars'Scientific&Technological Innovation(Grant No.BMU2022PYB022)。

摘  要:Background:The aim of the study was to compare the dynamic defocus curve on patients post-implantation of the extended depth-of-focus(EDOF)and monofocal intraocular lens(IOL).Methods:A total of 62 age-related cataract patients receiving phacoemulsification with implantation of TECNIS Symfony(ZXRoO)or monofocal IOLs were enrolled.The binocular static and dynamic defocus curves with corrected distance visual acuity were evaluated at one month postoperatively.Results:The ZXR00 group achieved signifcantly better intermediate(P=0.044)and near(P=0.017)visual acuity(VA)than the monofocal group.Two groups had similar uncorrected and corrected distance VA(P>0.05,respectively).The dynamic defocus curve revealed a smoother decline from 0.0 D to-2.0 D in the ZXRo0 group.Defocused dynamic VA in the ZXR00 group was significantly better(P<0.05)except at 0.0 D(P=0.724)and-0.5 D(P=0.176).The area under the curve(P=0.002)and corrected dynamic vision accommodation(P=0.001)derived from the dynamic defocus curves were better in the ZxRoo group.A positive correlation was observed between defocused dynamic and static VA in both groups(P<0.001).Multiple linear regression analysis indicated that defocused static VA and cor-rected dynamic vision accommodation were significant influential factors for the defocused dynamic VA from-1.0 D to-3.0 D(P<0.05).Conclusions:The EDOF IOL provided similar distant vision,better intermediate and near vision,and a better overall dynamic defocus curve than the monofocal IOL.The dynamic defocus curve may be comprehensively applied to evaluate the all-distance dynamic visual performance post-cataract surgery.

关 键 词:Dynamic defocus curve Age-related cataract Extended depth-of-focus intraocular lens Monofocal intraocularlens 

分 类 号:R779.6[医药卫生—眼科]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象