检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Sunisa Sintuwong Kanjana Leelapatranurak Orapan Aryasit Passorn Preechawai Mingkwan Lumyongsatien Ornvenus Nimitwongsakul Jugchawin Kanokkantapong Unnkade Bhaktikamala Yongyot Tuachob Jirapol Bhuntuveh Pennung Thongtong Waraporn Suvannapruk Jintamai Suwanprateeb
机构地区:[1]Department of Ophthalmology,Mettapracharak(Wat Rai Khing)Hospital,Nakhon Pathom 73210,Thailand [2]Department of Ophthalmology,Faculty of Medicine,Prince of Songkla University,Songkhla 90110,Thailand [3]National Metal and Materials Technology Center(MTEC),National Science and Technology Development Agency(NSTDA),Pathum Thani 12120,Thailand [4]Thammasat University Center of Excellence in Computational Mechanics and Medical Engineering,Thammasat University,Pathum Thani 12120,Thailand
出 处:《International Journal of Ophthalmology(English edition)》2024年第10期1857-1863,共7页国际眼科杂志(英文版)
基 金:Supported by the Mettapracharak grant;Thai Government Budget grant;Health Systems Research Institute grant;National Science and Technology Development Agency grant.
摘 要:AIM:To compare the exposure rate,infection rate,percentage of enhancement,and success rate between Medpor and the three-dimensional printed polyethylene(3DP-PE)orbital implant in a preliminary report.METHODS:This prospective,randomized,equivalence,controlled trial was conducted at two institutes.The equivalent margin was±10%.The sample size for the equivalence trial was 174 participants per group.Patients who were eligible for enucleations received either Medpor or 3DP-PE implants based on a randomized block of six.The surgeries were performed by five oculoplastic surgeons.The assessor and patients were masked.The magnetic resonance imaging(MRI)of the orbit was performed at least 6mo after operation and the fibrovascular ingrowth was analyzed using the Image J software.Follow-up continued at least 1y after surgery.The intention to treat and per protocol approaches were used.RESULTS:Totally 128 patients met the criteria in the report.Fifty Medpor and 553DP-PE cases completed the trial.The most common cause of blindness was trauma.The mean follow-up times of Medpor and 3DP-PE were 33 and 40mo respectively.The exposure rate was not statistically significant between two groups(6.0%and 7.3%),P<0.05,95%CI(-9.8%,+12.0%).The success rates were 94%(Medpor)and 92.7%(3DP-PE).No postoperative infection was reported.Nine patients had MRI tests and two had implant exposures with 66.3% enhancement at 75mo(Medpor)and 58% enhancement at 57mo(3DP-PE)postoperatively.CONCLUSION:There is no statistically significant difference in exposure rate and success rate between Medpor and 3DP-PE in enucleation in the report.However,we cannot conclude that they are equivalent in terms of the exposure rate and success rate because the 95%CI is wider than±10%.The infection rate is equivalent in both groups.
关 键 词:orbital implants eyeball enucleation polyethylene BLINDNESS eye injuries ORBIT
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.119.103.13