检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Yaxin Ye Zhechang Chen Shengzhang Zhang Paul Slezak Fei Lu Ruiqi Xie Dongwon Lee Guangqian Lan Enling Hu
机构地区:[1]State Key Laboratory of Resource Insects,College of Sericulture,Textile and Biomass Sciences,Southwest University,Chongqing 400715,China [2]Department of Cardiovascular Medicine,Yueqing People's Hospital.Wenzhou 325699,China [3]Ludwig Boltzmann Institute for Traumatology,AUVA Research Center,1200 Vienna,Austria [4]Department of Bionanotechnology and Bioconvergence Engineering and Department of Polymer-Nano Science and Technology,Jeonbuk National University,Jeonju,Chonbuk 54896,Republic of Korea [5]School of Fashion and Textiles,The Hong Kong Polytechnic University,Hong Kong,China
出 处:《Research》2024年第3期17-33,共17页研究(英文)
基 金:the National Natural Science Foundation of China(No.52103096);the Natural Science Foundation of Chongqing,China(cstb2022nscq-msx0555);the Fundamental Research Funds for Central Universities(No.SWU-XDPY22010).
摘 要:Thrombosis can cause life-threatening disorders. Unfortunately, current therapeutic methods for thrombosis using injecting thrombolytic medicines systemically resulted in unexpected bleeding complications. Moreover, the absence of practical imaging tools for thrombi raised dangers of undertreatment and overtreatment. This study develops a theranostic drug carrier, Pkr(IR-Ca/Pda-uPA)-cRGD, that enables real-time monitoring of the targeted thrombolytic process of deep vein thrombosis (DVT). Pkr(IR-Ca/Pda-uPA)-cRGD, which is prepared from a Pickering-emulsion-like system, encapsulates both near-infrared-II (NIR-II) contrast agent (IR-1048 dye, loading capacity: 28%) and urokinase plasminogen activators (uPAs, encapsulation efficiency: 89%), pioneering the loading of multiple drugs with contrasting hydrophilicity into one single-drug carrier. Upon intravenous injection, Pkr(IR-Ca/Pda-uPA)-cRGD considerably targets to thrombi selectively (targeting rate: 91%) and disintegrates in response to acidic thrombi to release IR-1048 dye and uPA for imaging and thrombolysis, respectively. Investigations indicate that Pkr(IR-Ca/Pda-uPA)-cRGD enabled real-time visualization of targeted thrombolysis using NIR-II imaging in DVT models, in which thrombi were eliminated (120 min after drug injection) without bleeding complications. This may be the first study using convenient NIR-II imaging for real-time visualization of targeted thrombolysis. It represents the precision medicine that enables rapid response to acquire instantaneous medical images and make necessary real-time adjustments to diagnostic and therapeutic protocols during treatment.
关 键 词:INFRARED enable eliminated
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.222