检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:卢卓禹 邓思成 许文浩 陈来军[1,2] LU Zhuoyu;DENG Sicheng;XU Wenhao;CHEN Laijun(School of Energy and Electrical Engineering,Qinghai University,Xining 810016,China;Department of Electrical Engineering,Tsinghua University,Beijing 100084,China)
机构地区:[1]青海大学能源与电气工程学院,西宁810016 [2]清华大学电机工程与应用电子技术系,北京100084
出 处:《高电压技术》2024年第10期4530-4539,I0003,共11页High Voltage Engineering
基 金:国家自然科学基金(U21A20146)。
摘 要:分布式控制是提高分布式发电系统运行灵活性和可靠性的重要技术手段,但其控制效果较依赖于各分布式电源之间快速、可靠的信息交互。实际系统中,通信延时往往难以避免,其存在可能使控制性能恶化,甚至导致系统失稳。为此,提出一种考虑通信延时的分布式发电系统高可靠协同控制策略。首先,分析通信延时对常规分布式控制系统的影响;其次,通过引入Artstein变换,将含延时系统的稳定性问题转换为无延时系统的控制器优化设计问题;在此基础上,针对延时导致系统响应性能恶化的问题,设计有限时间控制策略,在优化收敛速度的同时提升系统对设备频繁投切的适应性。多种工况的结果验证了控制策略在通信延时下具有更可靠的控制性能。Distributed consensus-based control is an important technical method to improve the flexibility and reliability of distributed generation system's operation;however,the control highly depends on the fast and reliable communication between distributed generators.In the practical system,the communication time delay is inevitable and will significantly affect the control performance and the stability of the system.Therefore,a highly reliable cooperative control strategy of distributed generation system considering communication time delays is proposed in this paper.Firstly,the influence of communication time delays on the conventional distributed control system is analyzed.Secondly,by introducing the Artstein transform,the stability problem of system with delay is transformed into the controller optimization design problem of system without delay.Moreover,in accordance with the problem that time delay will seriously affect the response performance of the system,a finite-time control strategy is designed,improving the convergence speed and the adaptability of the system under the frequent switching of equipment.The more reliable control performance of the control strategy under communication delay is verified by the results of various conditions.
关 键 词:分布式发电系统 一致性算法 通信延时 高可靠 分布式运行 协同控制
分 类 号:TM61[电气工程—电力系统及自动化]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.49