作 者:乔顺庆 田桂珍[1,2] 张建伟 韩小宇[1] QIAO Shunqing;TIAN Guizhen;ZHANG Jianwei;HAN Xiaoyu(College of Electric Power,Inner Mongolia University of Technology Hohhot 010000,Nei Mongol,China;Engineering Research Center of Large Energy Storage Technology of Ministry of Education,Hohhot 010080,Nei Mongol,China)
机构地区:[1]内蒙古工业大学电力学院,内蒙古呼和浩特010000 [2]大规模储能技术教育部工程研究中心,内蒙古呼和浩特010080
出 处:《储能科学与技术》2024年第11期3993-4004,共12页Energy Storage Science and Technology
基 金:内蒙古自治区科技重大专项(2020ZD0014);内蒙古自然科学基金项目(2021MS05003,2022MS05032)。
摘 要:在独立运行直流微电网中,由于接入大量电力电子变换装置,系统惯性较低,阻尼较小,系统稳定性较差,同时,新能源和负载的功率波动将引起母线电压波动,严重时会影响直流微电网的稳定运行。为增强系统惯性,本文研究基于参数自适应改进虚拟直流电机(virtual DC motor,VDCM)控制策略,提升母线电压暂态稳定性。介绍虚拟直流电机控制原理,建立储能控制系统的小信号模型,深入分析虚拟转动惯量、阻尼系数和电压调节器比例、积分参数对系统稳定性影响,以及母线电压波动过程中各波动阶段对参数大小的需求。在此基础上,建立虚拟转动惯量、比例系数和积分系数与母线电压偏差的函数关系式。根据电压偏差动态调节VDCM和电压调节器参数,缩短电压的扰动恢复时间的同时减小电压波动。通过搭建的RTDS和RCP硬件在环实验系统,验证所提控制策略的正确性与可行性。During the independent operation of DC microgrids,the integration of numerous power electronic conversion devices,coupled with the power fluctuations of renewable energy sources and variable loads,results in reduced inertia,lower damping,and compromised stability.These conditions often cause significant bus voltage fluctuations,potentially threatening the stable operation of the DC microgrid.To address these challenges,this paper investigates an enhanced virtual DC motor(VDCM)control strategy based on parameter adaptation to improve the transient stability of the bus voltage.The control principle of the virtual DC motor is introduced,and a small-signal model of the energy storage control system is established.An in-depth analysis is conducted on the influence of virtual inertia,damping coefficient,and voltage regulator proportional and integral parameters on system stability,highlighting the parameter requirements during each stage of bus voltage fluctuations.Based on this analysis,functional relationships between virtual inertia,proportional coefficient,integral coefficient,and bus voltage deviation are derived.By dynamically adjusting VDCM and voltage regulator parameters in response to voltage deviations,the proposed strategy effectively reduces recovery time under disturbances and minimizes voltage fluctuations.The correctness and feasibility of the proposed control strategy are validated through a hardware-in-loop experimental system utilizing a real-time digital simulator and rapid control prototyping.
关 键 词:直流微电网 储能控制 参数自适应 虚拟直流电机 硬件在环实验
分 类 号:TM912[电气工程—电力电子与电力传动]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.3