检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:尤柱 秦华[2] 孙建东[2] 靳琳 秦晨阳 YOU Zhu;QIN Hua;SUN Jiandong;JIN Lin;QIN Chenyang(School of Nanotechnology and Nanobionics,University of Science and Technology of China,Hefei 230026,China;Suzhou Institute of Nanotechnology and Nanobionics,Chinese Academy of Sciences,Suzhou 215123,China)
机构地区:[1]中国科学技术大学纳米技术与纳米仿生学院,合肥230026 [2]中国科学院苏州纳米技术与纳米仿生研究所,苏州215123
出 处:《微波学报》2024年第6期66-72,共7页Journal of Microwaves
基 金:国家自然科学基金(61975227)。
摘 要:自由空间的太赫兹电磁波与太赫兹天线/探针之间的耦合通常是通过波导或硅透镜来实现的。基于波导的耦合方案可以提供比透镜耦合方案更高的耦合效率,而此前AlGaN/GaN HEMT太赫兹探测器/混频器具有高阻抗的特性,因此一般采用硅透镜耦合。文中仿真设计了一种110 GHz的波导耦合型AlGaN/GaN HEMT太赫兹直接探测器,采用波导-微带过渡结构和微带线阻抗匹配结构使探测器的阻抗降低至275Ω,在降低热噪声电压的同时具有高的响应度。在设计好探测器各部分结构后,对其进行整体全波仿真、数据提取与后处理计算,最后可得到探测器的性能指标即噪声等效功率(NEP)。结果表明:在110 GHz的频率下,太赫兹探测器的NEP可达到22pW/√Hz,与透镜耦合型直接探测器灵敏度相当,其中该探测器中HEMT混频器的栅长和栅宽分别为1μm和150μm。仿真结果还表明通过将栅长从1μm缩减至100 nm,可以进一步降低探测器的NEP,提高探测器的灵敏度。The coupling between terahertz electromagnetic waves in free space and terahertz antennas/probes is usually achieved through waveguides or silicon lenses.Waveguide-based coupling schemes can provide higher coupling efficiency than lens coupling schemes,whereas previously AlGaN/GaN HEMT terahertz detectors/mixers had the characteristic of high impedance and therefore generally used Si-lens coupling.In this paper,a waveguide-coupled AlGaN/GaN HEMT terahertz direct detector is simulated and designed for 110 GHz applications.A waveguide-microstrip transition structure and the microstrip line impedance matching structure are applied to reduce the detector impedance to 275Ω,which provides high responsivity while reducing the thermal noise voltage.After designing the structure of each part of the detector,the overall full-wave simulation,data extraction and post-processing are performed,and finally the figure of merit of the detector,i.e.,the noise-equivalent power(NEP),can be obtained.The results show that the NEP of the terahertz detector is about 22pW/√Hzat 110 GHz,which is comparable to the sensitivity of the Si-lens coupled terahertz direct detector,where the gate length and gate width of the HEMT mixer in this detector are 1μm and 150μm,respectively.The simulation results suggest the NEP could be further reduced and the detector sensitivity can be improved by shrinking the gate length from 1μm to 100 nm.
分 类 号:TN36[电子电信—物理电子学]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.141.43.16