检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:曾捷 杜春 赖祺宇 余翔 李树林 Zeng Jie;Du Chun;Lai Qiyu;Yu Xiang;Li Shulin(Shenzhen Expressway Construction and Development Co.,Ltd.,Shenzhen;Chang’an University,Xi’an)
机构地区:[1]深圳高速建设发展有限公司,深圳 [2]长安大学,西安710064
出 处:《暖通空调》2025年第1期70-79,共10页Heating Ventilating & Air Conditioning
摘 要:以某分岔隧道为例,对发生火灾时不同通风方案下隧道内的温度场及烟气的蔓延规律进行了模拟研究,分析了匝道风压、主隧道出口段风压、主隧道加宽段风压对火灾烟气输运特性的影响。工况1与工况2分别采用提高匝道风压与提高主隧道出口段风压的通风方案,对比2种工况下温度场变化得知主隧道出口段通风效果优于匝道。工况3采用提高主隧道加宽段风压的通风方案,随着主隧道加宽段风压的增大,主隧道内高于60℃的高温区域不断缩小,主隧道出口段与匝道2 m高度内温度逐渐降低,主隧道加宽段风压的增大对隧道排烟有利,但并不显著。工况4采用增大匝道风压的通风方案,主隧道2 m高度内温度降低,匝道2 m高度内温度升高,增大匝道风压,匝道的排烟效果明显,由于匝道断面小,可考虑作为排烟通道。Taking a bifurcated tunnel as an example,a simulation study is carried out on the temperature field and smoke spread law in the tunnel under different ventilation schemes during a fire,and the impacts of the wind pressure in the ramp,the wind pressure in the exit section of the main tunnel,and the wind pressure in the widened section of the main tunnel on the smoke transportation characteristics of the fire are analysed.The ventilation scheme of increasing the wind pressure in the ramp and the exit section of the main tunnel is adopted in condition 1 and condition 2,respectively.Comparing the temperature field changes under the two conditions,it is found that the ventilation effect in the exit section of the main tunnel is better than that in the ramp.Condition 3 adopts a ventilation scheme to increase the wind pressure in the widened section of the main tunnel.As the wind pressure in the widened section of the main tunnel increases,the high temperature area above 60℃in the main tunnel continues to shrink,and the temperature within the height of 2 m in the exit section of the main tunnel and the ramp gradually decreases.The increase of the wind pressure in the widened section of the main tunnel is beneficial to tunnel smoke exhaust,but it is not significant.Condition 4 adopts the ventilation scheme of increasing the wind pressure in the ramp.The temperature within the height of 2 m in the main tunnel decreases,and the temperature within the height of 2 m in the ramp increases.If the wind pressure in the ramp is increased,the smoke exhaust effect of the ramp is obvious.Due to the small cross-section of the ramp,it can be considered as a smoke exhaust channel.
关 键 词:分岔隧道 火灾 排烟 烟气输运 通风 风压 主隧道 匝道
分 类 号:U458.1[建筑科学—桥梁与隧道工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.171