Comparison of pseudophakic retinal straylight in spherical/aspherical and hydrophobic/hydrophilic intraocular lens  被引量:2

Comparison of pseudophakic retinal straylight in spherical/aspherical and hydrophobic/hydrophilic intraocular lens

在线阅读下载全文

作  者:Yong Tang Hui Song Jing Chen Xin Tang 

机构地区:[1]Cataract Center, Tianjin Eye Hospital

出  处:《International Journal of Ophthalmology(English edition)》2015年第6期1146-1150,共5页国际眼科杂志(英文版)

摘  要:AIM: To study the potential reasons of increased straylight in pseudophakic eyes. METHODS: Cross -sectional study. Seventy patients diagnosed as bilateral age-related cataract and implanted with Tecnis ZA9003, Sensar AR40e, SA6OAT, XLSTABI ZO or Akeros AO intraocular lens (IOL) were enrolled in this research. Straylight was measured by a C -Quant straylight meter three to four weeks postoperatively. Five different modalities of IOL, including spherical/aspherical optics and hydrophobic/hydrophilic material were tested in this study. Normal as well as dilated pupils were used. The main outcome variable for straylight measurement was the logarithmic straylight parameter, log(s). RESULTS: The straylight parameter increased significantly after pupil dilation (P<0.05). Straylight of aspherical IOL was significantly higher after pupil dilation (P<0.06) compared to spherical IOL. In normal pupil, straylight of hydrophobic IOL was significant higher when compared with hydrophilic IOL (P<0.05). CONCLUSION: Straylight and visual acuity stand for the different aspects of visual function. Several factors including pupil diameter, optic material, aspherical design of IOL influence intraocular light scattering in pseudophakic eyes. Further investigation was needed to study the impact of optic material and optic surface design on pseudophakic straylight.AIM: To study the potential reasons of increased straylight in pseudophakic eyes. METHODS: Cross -sectional study. Seventy patients diagnosed as bilateral age-related cataract and implanted with Tecnis ZA9003, Sensar AR40e, SA6OAT, XLSTABI ZO or Akeros AO intraocular lens (IOL) were enrolled in this research. Straylight was measured by a C -Quant straylight meter three to four weeks postoperatively. Five different modalities of IOL, including spherical/aspherical optics and hydrophobic/hydrophilic material were tested in this study. Normal as well as dilated pupils were used. The main outcome variable for straylight measurement was the logarithmic straylight parameter, log(s). RESULTS: The straylight parameter increased significantly after pupil dilation (P<0.05). Straylight of aspherical IOL was significantly higher after pupil dilation (P<0.06) compared to spherical IOL. In normal pupil, straylight of hydrophobic IOL was significant higher when compared with hydrophilic IOL (P<0.05). CONCLUSION: Straylight and visual acuity stand for the different aspects of visual function. Several factors including pupil diameter, optic material, aspherical design of IOL influence intraocular light scattering in pseudophakic eyes. Further investigation was needed to study the impact of optic material and optic surface design on pseudophakic straylight.

关 键 词:light scattering retinal straylight PSEUDOPHAKIA 

分 类 号:R779.6[医药卫生—眼科]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象