A prediction model for guiding tumor microwave ablation surgery based on simulation  

在线阅读下载全文

作  者:Lu Qian Yamin Yang Pan Chen Jia Liu Xiaofei Jin Zhiyu Qian Chunxiao Chen 

机构地区:[1]Department of Biomedical Engineering Nanjing University of Aeronautics and Astronautics,Nanjing,P.R.China [2]Hunan Cancer Hospital and The Affiliated Cancer Hospital of Xiangya School of Medicine Central South University,Changsha 410013 Hunan Province,P.R.China

出  处:《Journal of Innovative Optical Health Sciences》2025年第1期85-99,共15页创新光学健康科学杂志(英文)

基  金:supported by the National Major Scientific Instruments and Equipment Development Project Funded by the National Natural Science Foundation of China(81827803);the Jiangsu Province Key Research and Development Program(Social Development)Project(BE2020705).

摘  要:Purpose:The major limitation of tumor microwave ablation(MWA)operation is the lack of predictability of the ablation zone before surgery.Operators rely on their individual experience to select a treatment plan,which is prone to either inadequate or excessive ablation.This paper aims to establish an ablation prediction model that guides MWA tumor surgical planning.Methods:An MWA process was first simulated by incorporating electromagnetic radiation equations,thermal equations,and optimized biological tissue parameters(dynamic dielectric and thermophysical parameters).The temperature distributions(the short/long diameters,and the total volume of the ablation zone)were then generated and verified by 60 cases ex vivo porcine liver experiments.Subsequently,a series of data were obtained from the simulated temperature distributions and to further fit the novel ablation coagulated area prediction model(ACAPM),thus rendering the ablation-dose table for the guiding surgical plan.The MWA clinical patient data and clinical devices suggested data were used to validate the accuracy and practicability of the established predicted model.Results:The 60 cases ex vivo porcine liver experiments demonstrated the accuracy of the simulated temperature distributions.Compared to traditional simulation methods,our approach reduces the long-diameter error of the ablation zone from 1.1 cm to 0.29 cm,achieving a 74%reduction in error.Further,the clinical data including the patients'operation results and devices provided values were consistent well with our predicated data,indicating the great potential of ACAPM to assist preoperative planning.

关 键 词:Microwave ablation ablation simulation microwave prediction model dynamic tissue parameter 

分 类 号:R730.5[医药卫生—肿瘤] R318[医药卫生—临床医学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象