检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Lu Qian Yamin Yang Pan Chen Jia Liu Xiaofei Jin Zhiyu Qian Chunxiao Chen
机构地区:[1]Department of Biomedical Engineering Nanjing University of Aeronautics and Astronautics,Nanjing,P.R.China [2]Hunan Cancer Hospital and The Affiliated Cancer Hospital of Xiangya School of Medicine Central South University,Changsha 410013 Hunan Province,P.R.China
出 处:《Journal of Innovative Optical Health Sciences》2025年第1期85-99,共15页创新光学健康科学杂志(英文)
基 金:supported by the National Major Scientific Instruments and Equipment Development Project Funded by the National Natural Science Foundation of China(81827803);the Jiangsu Province Key Research and Development Program(Social Development)Project(BE2020705).
摘 要:Purpose:The major limitation of tumor microwave ablation(MWA)operation is the lack of predictability of the ablation zone before surgery.Operators rely on their individual experience to select a treatment plan,which is prone to either inadequate or excessive ablation.This paper aims to establish an ablation prediction model that guides MWA tumor surgical planning.Methods:An MWA process was first simulated by incorporating electromagnetic radiation equations,thermal equations,and optimized biological tissue parameters(dynamic dielectric and thermophysical parameters).The temperature distributions(the short/long diameters,and the total volume of the ablation zone)were then generated and verified by 60 cases ex vivo porcine liver experiments.Subsequently,a series of data were obtained from the simulated temperature distributions and to further fit the novel ablation coagulated area prediction model(ACAPM),thus rendering the ablation-dose table for the guiding surgical plan.The MWA clinical patient data and clinical devices suggested data were used to validate the accuracy and practicability of the established predicted model.Results:The 60 cases ex vivo porcine liver experiments demonstrated the accuracy of the simulated temperature distributions.Compared to traditional simulation methods,our approach reduces the long-diameter error of the ablation zone from 1.1 cm to 0.29 cm,achieving a 74%reduction in error.Further,the clinical data including the patients'operation results and devices provided values were consistent well with our predicated data,indicating the great potential of ACAPM to assist preoperative planning.
关 键 词:Microwave ablation ablation simulation microwave prediction model dynamic tissue parameter
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.127