检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Yuna Jung Daniel Gulick Jennifer Blain Christen
出 处:《Microsystems & Nanoengineering》2024年第6期391-402,共12页微系统与纳米工程(英文)
基 金:supported by DOD-ARMY:Army Medical Research Acquisition Activity(USAMRAA)under a CDMRP(Congressionally Directed Medical Research Program)grant W81XWH2010805,“A Miniaturized Valve that Mimics Functional Arachnoid Granulations to Treat Hydrocephalus”.
摘 要:Hydrocephalus is characterized by the accumulation of excess cerebrospinal fluid(CSF)in the cranium due to an imbalance between production and absorption of CSF.The standard treatment involves the implantation of a shunt to divert excess CSF into the peritoneal cavity,but these shunts exhibit high failure rates over time.In pursuit of improved reliability and performance,this study proposes a miniaturized valve designed to mimic the natural one-way valve function of the arachnoid granulations and thereby replace the shunts.A benchtop testing setup was employed to characterize the behavior of the fabricated valve.Additionally,an animal study was conducted to assess the valve’s in vivo performance.This involved the injection of saline into the lateral ventricle to elevate intracranial pressure(ICP),followed by the drainage of the saline through the valve inserted into the cisterna magna(CM)to reduce pressure.Our prototype features a silicone duckbill valve design combined with a silicone tube as an inlet.Through benchtop testing,the valve exhibited unidirectional flow with negligible reverse leakage,revealing that critical parameters such as the width of the fluid channel(W)and bill length(L)could be controlled to optimize valve performance.Notably,the valve configuration with W=0.8mm and L<0.5mm achieved the lowest cracking pressure(2.22±0.07 mmHg)and outflow resistance(22.00±0.70 mmHg/mL/min)within the low cracking pressure range of conventional shunts.Our observations of the in vivo test demonstrated that when untreated states,pressure differences from baseline to peak exceeded 20 mmHg due to the absence of drainage,resulting in sustained pressure elevation.Conversely,upon treating states by removing the clamp,pressure differences from baseline to peak remained below 5 mmHg,indicating effective drainage of injected saline through the valve.These promising results highlight the potential of the miniaturized duckbill valve as an alternative for ICP management in hydrocephalus,offering improved control and reli
分 类 号:R318[医药卫生—生物医学工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.7