检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:侯书敏 吴珂 王李平 吴光杰[1,2] 刘仁荣 熊辉煌[3] 赵佳莹 HOU Shumin;WU Ke;WANG Liping;WU Guangjie;LIU Renrong;XIONG Huihuang;ZHAO Jiaying(School of Life Science,Jiangxi Science&Technology Normal University,Nanchang 330013,China;Jiangxi Province Key Laboratory of Natural Microbial Medicine Research,Jiangxi Science&Technology Normal University,Nanchang 330013,China;School of Chemistry and Chemical Engineering,Nanchang University,Nanchang 330031,China)
机构地区:[1]江西科技师范大学生命科学学院,江西南昌330013 [2]江西科技师范大学天然微生物药物研究江西省重点实验室,江西南昌330013 [3]南昌大学化学化工学院,江西南昌330031
出 处:《南昌大学学报(理科版)》2025年第1期76-81,共6页Journal of Nanchang University(Natural Science)
基 金:国家自然科学基金资助项目(31960501);江西省教育厅科技落地计划(KJLD14067);江西省职业早期青年科技人才培养专项项目(20244BCE52251)。
摘 要:为探索免疫亲和柱串联高效液相色谱(immunoaffinity column-high performance liquid chromatography,IAC-HPLC)监测IAC柱容量的方法,本研究利用赭曲霉毒素A(Ochratoxin A,OTA)与乙二胺发生缩合反应,纯化获得高纯度OTA结构修饰物(OTA-X),通过光谱、质谱对其进行了鉴定,以IAC的抗体建立了酶联免疫吸附法(Enzyme-linked immunosorbent assay,ELISA),测得OTA与OTA-X在竞争抑制曲线的IC50值分别为0.71和9.97 ng·mL^(-1),表明OTA-X与抗体的亲和力低于OTA。以OTA-X作为IAC柱容量的示踪物,建立了IAC-HPLC方法,监测添加不同浓度的OTA-X和OTA在IAC的回收率。结果表明:在柱容量范围内,OTA的回收率大于80%,而OTA-X的回收率随着OTA的增加而降低,总结合量大于柱容量,说明OTA-X可以作为IAC柱容量的示踪物监测柱容量,且不影响OTA的检测结果,为提高OTA检测的准确度提供了新方法。In order to monitor IAC column capacity in the immunoaffinity column-High performance liquid chromatography(IAC-HPLC)method for analyzing Ochratoxin A(OTA),OTA was reacted with ethylenediamine by a condensation reaction to acquire a structural modification OTA-X.After purification,OTA-X was identified by spectroscopy and mass spectrometry techniques.An Enzyme-Linked immunosorbent assay(ELISA)was developed based on IAC antibodies.The IC50 values for OTA and OTA-X in the competitive inhibition curves of ELISA were 0.71 and 9.97 ng·mL^(-1),respectively,indicating that the affinity for antibodies was lower than that of OTA.Using OTA-X as the tracer for assessing IAC column capacity,the recovery rates of OTA and OTA-X at different concentrations in IAC were monitored.The results showed that,within the operational column capacity range,the recovery rate for OTA remained relatively stable above 80%,while the recovery rate of OTA-X decreased with the increase of OTA and the total binding amount was above the capacity of IAC.This research showed that OTA-X can serve as a tracer for monitor IAC column capacity without affecting the accuracy of detecting OTA,providing an innovative method to enhance precision in detecting OTA.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.7