职业悲伤反应量表在实习护生中的应用评价  

Psychometric properties of Professional Grief Response Scale in nursing interns

在线阅读下载全文

作  者:林苑红 文泽 刘静婷 高钰琳[1] LIN Yuanhong;WEN Ze;LIU Jingting;GAO Yulin(School of Nursing,Southern Medical University,Guangzhou 510515,China)

机构地区:[1]南方医科大学护理学院,广东广州510515

出  处:《护理学报》2025年第7期11-15,共5页Journal of Nursing(China)

摘  要:目的基于项目反应理论和经典测量理论检验职业悲伤反应量表在实习护生中的信效度。方法便利选取450名实习护生进行问卷调查,运用项目反应理论和经典测量理论方法评价量表信效度。结果最终形成的量表包含情感反应(14个条目)、生理和认知反应(16个条目)2个维度,共30个条目。项目反应理论结果显示各条目的加权均方拟合统计量和未加权均方拟合统计量范围在0.840~1.400;条目难度与个体能力的平均值相差0.750 logits;“有点符合”和“比较符合”选项的阈值差值偏小;不同性别和年龄的实习护生的项目功能差异值均<0.640 logits。个体和条目的信度范围在0.840~0.980,个体和条目的分离指数范围在2.290~6.860。经典测量理论结果显示2因子的累计方差贡献率为52.472%,模型拟合配适度符合要求,且聚合效度可靠;量表的Cronbachα系数为0.931,2个维度的Cronbachα系数分别为0.865、0.955。结论修订后的职业悲伤反应量表具有良好的心理测量学质量,可用于实习护生的职业悲伤测评。Objective To test the reliability and validity of the Professional Grief Reaction Scale among nursing interns based on Item Response Theory(IRT)and Classical Test Theory(CTT).Methods A convenience sample of 450 nursing students with internship experience was surveyed by using the Professional Grief Reaction Scale.Both IRT and CTT were used to evaluate the scale’s reliability and validity.Results The final scale consisted of two dimensions:Emotional Response(14 items)and Physical and Cognitive Response(16 items).IRT indicated that the information-weighted mean square fit statistic(Infit MNSQ)and the unweighted mean square fit statistic(Outfit MNSQ)for all items ranged from 0.840 to 1.400.The average difference between item difficulty and individual ability was 0.750 logits.The threshold differences between the options"somewhat agree"and"fairly agree"were small.Differential item functioning values for interns of different genders and ages were all below 0.640 logits.The reliability of individuals and items ranged from 0.840 to 0.980,and the separation indices ranged from 2.290 to 6.860.According to CTT,the cumulative variance contribution rate of the two factors was 52.472%;the model fit met requirements,and the convergent validity was reliable.The Cronbach’s alpha coefficient for the scale was 0.931,and for the two dimensions,that was 0.865 and 0.955,respectively.Conclusion The revised Professional Grief Reaction Scale demonstrates good psychometric properties and can be used to assess professional grief among nursing interns.

关 键 词:职业悲伤 实习护生 信效度 项目反应理论 经典测量理论 

分 类 号:R471[医药卫生—护理学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象