Flow-Injection Electrochemiluminescence Detecting Rifampicin Based on Its Sensitizing Effect  被引量:1

Flow-Injection Electrochemiluminescence Detecting Rifampicin Based on Its Sensitizing Effect

在线阅读下载全文

作  者:马红燕 郑行望 章竹君 

机构地区:[1]College of Chemistry and Material Science, Shaanxi Normal University, Xi'an , Shaanxi 710062, China [2]College of Chemistry and Chemical Engineering, Provincial Key Laboratory of Chemical Reaction Engineering, Yan'an University, Yan'an, Shaanxi 716000, China

出  处:《Chinese Journal of Chemistry》2004年第3期279-282,共4页中国化学(英文版)

基  金:Project supported by the National Natural Science Foundation of China (No. 397301610).

摘  要:MA, Hong Yana,b( ZHENG, Xing-Wanga ZHANG, Zhu-Jun*,aa College of Chemistry and Material Science, Shaanxi Normal University, Xi′an , Shaanxi 710062, China b College of Chemistry and Chemical Engineering, Provincial Key Laboratory of Chemical Reaction Engineering, Yan′an University, Yan′an, Shaanxi 716000, China A new flow-injection electrogenerated chemiluminescence (ECL) method for the determination of rifampicin was developed. The method is based on the sensitizing effect of rifampicin on the weak ECL signal of electrochemical oxidation of luminol on the surface of the platinum flake electrode in the medium of 0.02 mol·L-1 Na2B4O7. This ECL response is in the range of 1.0×10-84.0×10-6 mol·L-1 rifampicin with a detection limit of 8.0×10-9 mol·L-1. The relative standard deviation is 1.8%. This method has been applied successfully to the determination of rifampicin in capsule, ocustilla and urine samples.MA, Hong Yana,b( ZHENG, Xing-Wanga ZHANG, Zhu-Jun*,aa College of Chemistry and Material Science, Shaanxi Normal University, Xi′an , Shaanxi 710062, China b College of Chemistry and Chemical Engineering, Provincial Key Laboratory of Chemical Reaction Engineering, Yan′an University, Yan′an, Shaanxi 716000, China A new flow-injection electrogenerated chemiluminescence (ECL) method for the determination of rifampicin was developed. The method is based on the sensitizing effect of rifampicin on the weak ECL signal of electrochemical oxidation of luminol on the surface of the platinum flake electrode in the medium of 0.02 mol·L-1 Na2B4O7. This ECL response is in the range of 1.0×10-84.0×10-6 mol·L-1 rifampicin with a detection limit of 8.0×10-9 mol·L-1. The relative standard deviation is 1.8%. This method has been applied successfully to the determination of rifampicin in capsule, ocustilla and urine samples.

关 键 词:electrogenerated chemiluminescence RIFAMPICIN LUMINOL 

分 类 号:O657.3[理学—分析化学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象