On-Line Independent Tap-Changing of Each Feeder Supplied by a Low Voltage Distribution Transformer  

On-Line Independent Tap-Changing of Each Feeder Supplied by a Low Voltage Distribution Transformer

在线阅读下载全文

作  者:David Johnston 

机构地区:[1]Faculty of Engineering and Environment, Northumbria University, Newcastle upon Tyne, UK

出  处:《Journal of Power and Energy Engineering》2014年第4期388-394,共7页电力能源(英文)

摘  要:An on-line tap-changing circuit was developed for use with low voltage transformers (10 kV/380 V, or equivalent), in which the tap positions could be set independently for each low voltage feeder. This allows for possible variation in loads and distributed generation between different feeders fed from a given transformer, allowing the line voltages to be kept within limits on all feeders. A combination of computer simulation and practical experiments was used. A model constructed in Excel gave preliminary results, which was used to specify a more detailed model in Matlab? Simulink. A small-scale 220/380 V distribution network was constructed, with currents limited to 5 A per phase. Finally, a rotary switch was constructed, suitable for currents up to 500 A, which would be required for a full-scale low voltage distribution network. The results showed that the voltage could be kept within limits, even with a large difference in load and distributed generation from one feeder to another.An on-line tap-changing circuit was developed for use with low voltage transformers (10 kV/380 V, or equivalent), in which the tap positions could be set independently for each low voltage feeder. This allows for possible variation in loads and distributed generation between different feeders fed from a given transformer, allowing the line voltages to be kept within limits on all feeders. A combination of computer simulation and practical experiments was used. A model constructed in Excel gave preliminary results, which was used to specify a more detailed model in Matlab? Simulink. A small-scale 220/380 V distribution network was constructed, with currents limited to 5 A per phase. Finally, a rotary switch was constructed, suitable for currents up to 500 A, which would be required for a full-scale low voltage distribution network. The results showed that the voltage could be kept within limits, even with a large difference in load and distributed generation from one feeder to another.

关 键 词:Tap-Changing ON-LINE Feeders INDEPENDENT 

分 类 号:R73[医药卫生—肿瘤]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象