Diagnostic Validity of Cica Beta Test 1 for the Detection of Extended Spectrum Beta-Lactamase (ESBL) Producing Gram Negative Bacteria by Comparing with Phenotypic Method  

Diagnostic Validity of Cica Beta Test 1 for the Detection of Extended Spectrum Beta-Lactamase (ESBL) Producing Gram Negative Bacteria by Comparing with Phenotypic Method

在线阅读下载全文

作  者:Mostaqimur Rahman Hafiza Sultana Abdullahil Mosawuir Latifa Akhter Abdullah Yusuf 

机构地区:[1]Department of Microbiology, Rangpur Medical College, Rangpur, Bangladesh [2]Department of Physiology, Rangpur Medical College, Rangpur, Bangladesh [3]Department of Skin & VD, Rangpur Medical College, Rangpur, Bangladesh [4]Department of Microbiology, National Institute of Neuroscience & Hospital, Dhaka, Bangladesh

出  处:《Advances in Infectious Diseases》2019年第1期39-48,共10页传染病进展(英文)

摘  要:Background: Detection of extended spectrum beta lactamase producing bacteria is an important issue in the clinical settings. Objective: The purpose of the present study was to validate the Cica Beta Test 1 for detection of extended spectrum beta-lactamase (ESBL) producing bacteria. Method: This analytical type of cross-sectional study was carried out in the Department of Microbiology and Immunology at Bangabandhu Sheikh Mujib Medical University (BSMMU), Dhaka from January 2006 to December 2006 for a period of one (01) year. All the patients presented with the clinical features of urinary tract infection and surgical as well as burn wound infection at any age with both sexes were selected as study population. All bacteria were isolated and identified by their colony morphology, staining characters, pigment production, motility and other relevant biochemical tests. Phenotypic confirmation of ESBLs producing isolates were done by inhibitor potentiated disc diffusion test according to CLSI recommendation. The Cica Beta Test 1 was performed according to the manufacturer’s instructions. Result: A total number of 288 Gram negative bacteria were isolated. Among these isolates Cica Beta test 1 was positive in 97 strains and phenotypic confirmatory test was positive in 89 strains. The test sensitivity of Cica Beta Test 1 was 100% (95% CI 95.9% to 100.0%). Specificity of the test was 96.0% (95% CI 92.2% to 98.2%). The positive predictive value (PPV) and negative predictive value (NPV) were 92.7% (95% CI 84.5% to 95.7%) and 100.0% (95% CI 98.0% to 100.0%) respectively. The accuracy of the test was 97.2% (95% CI 95.1% to 99.1%). Area under ROC curve = 0.980 (95% CI 0.964 to 0.996);p value 0.0001. Conclusion: In conclusion, Cica Beta Test 1 is very high sensitivity and specificity for the detection of ESBL from Gram negative bacteria.Background: Detection of extended spectrum beta lactamase producing bacteria is an important issue in the clinical settings. Objective: The purpose of the present study was to validate the Cica Beta Test 1 for detection of extended spectrum beta-lactamase (ESBL) producing bacteria. Method: This analytical type of cross-sectional study was carried out in the Department of Microbiology and Immunology at Bangabandhu Sheikh Mujib Medical University (BSMMU), Dhaka from January 2006 to December 2006 for a period of one (01) year. All the patients presented with the clinical features of urinary tract infection and surgical as well as burn wound infection at any age with both sexes were selected as study population. All bacteria were isolated and identified by their colony morphology, staining characters, pigment production, motility and other relevant biochemical tests. Phenotypic confirmation of ESBLs producing isolates were done by inhibitor potentiated disc diffusion test according to CLSI recommendation. The Cica Beta Test 1 was performed according to the manufacturer’s instructions. Result: A total number of 288 Gram negative bacteria were isolated. Among these isolates Cica Beta test 1 was positive in 97 strains and phenotypic confirmatory test was positive in 89 strains. The test sensitivity of Cica Beta Test 1 was 100% (95% CI 95.9% to 100.0%). Specificity of the test was 96.0% (95% CI 92.2% to 98.2%). The positive predictive value (PPV) and negative predictive value (NPV) were 92.7% (95% CI 84.5% to 95.7%) and 100.0% (95% CI 98.0% to 100.0%) respectively. The accuracy of the test was 97.2% (95% CI 95.1% to 99.1%). Area under ROC curve = 0.980 (95% CI 0.964 to 0.996);p value 0.0001. Conclusion: In conclusion, Cica Beta Test 1 is very high sensitivity and specificity for the detection of ESBL from Gram negative bacteria.

关 键 词:Diagnostic Validity Cica BETA Test 1 EXTENDED SPECTRUM BETA-LACTAMASE ESBL Gram Negative Bacteria PHENOTYPIC Method 

分 类 号:R73[医药卫生—肿瘤]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象