检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Massimo Bolognesi Diletta Bolognesi
机构地区:[1]General Practice Medicine-Primary Care, Cesena, Italy [2]Territorial Medicine-Primary Care, Cesena, Italy
出 处:《Case Reports in Clinical Medicine》2013年第9期521-524,共4页临床医学病理报告(英文)
摘 要:Background: Many patients are affected by idiopathicbronchiolitis obliterans organizing pneumonia (BOOP). There are several known causes of BOOP, and several systemic disorders have BOOP as an associated primary pulmonary lesion. Numerous agents including cytotoxic and noncytotoxic drugs have the potential to cause pulmonary toxicity. Descriptions of amiodarone-related BOOP continue to be reported throughout the world. Case Report: We reported a patient with original clinical presentation who developed recurrent sustained ventricular tachycardia (SVT) despite the presence of implantable cardioverter-defibrillator (ICD), hypoxaemia and interstitial pneumonitis in both lung bases. After percutaneous transluminal coronary angioplasty, he developed bronchiolitis obliterans organizing pneumonia (BOOP). Conclusions: To our knowledge, such complications after percutaneous coronary procedure in patients with amiodarone therapy for arrhythmia prophylaxis, are not very frequent in literature.Background: Many patients are affected by idiopathicbronchiolitis obliterans organizing pneumonia (BOOP). There are several known causes of BOOP, and several systemic disorders have BOOP as an associated primary pulmonary lesion. Numerous agents including cytotoxic and noncytotoxic drugs have the potential to cause pulmonary toxicity. Descriptions of amiodarone-related BOOP continue to be reported throughout the world. Case Report: We reported a patient with original clinical presentation who developed recurrent sustained ventricular tachycardia (SVT) despite the presence of implantable cardioverter-defibrillator (ICD), hypoxaemia and interstitial pneumonitis in both lung bases. After percutaneous transluminal coronary angioplasty, he developed bronchiolitis obliterans organizing pneumonia (BOOP). Conclusions: To our knowledge, such complications after percutaneous coronary procedure in patients with amiodarone therapy for arrhythmia prophylaxis, are not very frequent in literature.
关 键 词:PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY AMIODARONE BOOP
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.15