作 者:Kazumitsu Nawata Moriyo Kimura
机构地区:[1]Graduate School of Engineering, University of Tokyo, Tokyo, Japan [2]The Public Health Institute, Tokyo, Japan
出 处:《Health》2017年第3期506-519,共14页健康(英文)
摘 要:In this paper, we evaluate the difference between the first and second measurements of blood pressure (BP) when BP is measured twice using the results of 17,775 medical checkups. The two measurements for both systolic BP (SBP) and the diastolic BP (DBP) fluctuated a large amount even though they were measured at a short interval. The first measurements were 6.7 and 2.4 mmHg higher than the second ones for SBP and DBP, suggesting a white coat effect. Then, the factors that might affect the differences between the two measurements were analyzed by the regression models. For both SBP and DBP, the difference increased as the first measurement increased. Age, gender, BMI and alcohol consumption were other important factors affecting the difference. In the case of a typical male individual, the typical criteria for hypertension of 140/90, 160/100 and 180/110 mmHg criteria in the first measurement would correspond to 135/86, 150/94 and 165/102 mmHg in the second measurement. The necessity of developing accurate and cost-efficient BP measurement methods is strongly suggested.In this paper, we evaluate the difference between the first and second measurements of blood pressure (BP) when BP is measured twice using the results of 17,775 medical checkups. The two measurements for both systolic BP (SBP) and the diastolic BP (DBP) fluctuated a large amount even though they were measured at a short interval. The first measurements were 6.7 and 2.4 mmHg higher than the second ones for SBP and DBP, suggesting a white coat effect. Then, the factors that might affect the differences between the two measurements were analyzed by the regression models. For both SBP and DBP, the difference increased as the first measurement increased. Age, gender, BMI and alcohol consumption were other important factors affecting the difference. In the case of a typical male individual, the typical criteria for hypertension of 140/90, 160/100 and 180/110 mmHg criteria in the first measurement would correspond to 135/86, 150/94 and 165/102 mmHg in the second measurement. The necessity of developing accurate and cost-efficient BP measurement methods is strongly suggested.
关 键 词:BLOOD PRESSURE Measurement Hypertension White COAT Effect Medical CHECKUP FLUCTUATION of BLOOD PRESSURE
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.117