The AL-SENSE Test is Reliable for Detection of Second Trimester Amniotic Fluid  

The AL-SENSE Test is Reliable for Detection of Second Trimester Amniotic Fluid

在线阅读下载全文

作  者:Marwan Odeh Ella Ophir Hadar Kesari-Shoham Olga Maximovsky Jacob Bornstein 

机构地区:[1]不详

出  处:《International Journal of Clinical Medicine》2011年第3期307-309,共3页临床医学国际期刊(英文)

摘  要:Objective: To validate the reliability and stability of the AL-SENSE panty-liner for detection of amniotic fluid in the second trimester. Study design: Amniotic fluid drawn during amniocentesis between 16 to 23 weeks of gestation was used for the study.100 μl and 400 μl of amniotic fluid, were dripped onto two panty liners, respectively. After 5 minutes the indicator strip was removed from the AL-SENSE, dried and examined. The color was recorded at time 0 and 5 minutes, and then every 10 minutes for the first 30 minutes, then at 1, 2, 6 and 12 hours. Results: 50 women were enrolled and 49 completed the study. 100% of both volume samples changed color from yellow to blue during the first 5 minutes and remained stable after twelve hours of follow-up. In the 100 μl subgroup, seven of the 49 samples (14.3%) had a delayed color change and in the 400 μl subgroup one of 49 (2.04%) had a delay in change of color. Conclusion: Amniotic fluid drawn during amniocentesis at weeks 16 - 23 of gestation have a positive, stable staining effect on the AL-SENSE panty liner. Hence, AL-SENSE may be reliable for detection of amniotic fluid leakage during the second trimester.Objective: To validate the reliability and stability of the AL-SENSE panty-liner for detection of amniotic fluid in the second trimester. Study design: Amniotic fluid drawn during amniocentesis between 16 to 23 weeks of gestation was used for the study.100 μl and 400 μl of amniotic fluid, were dripped onto two panty liners, respectively. After 5 minutes the indicator strip was removed from the AL-SENSE, dried and examined. The color was recorded at time 0 and 5 minutes, and then every 10 minutes for the first 30 minutes, then at 1, 2, 6 and 12 hours. Results: 50 women were enrolled and 49 completed the study. 100% of both volume samples changed color from yellow to blue during the first 5 minutes and remained stable after twelve hours of follow-up. In the 100 μl subgroup, seven of the 49 samples (14.3%) had a delayed color change and in the 400 μl subgroup one of 49 (2.04%) had a delay in change of color. Conclusion: Amniotic fluid drawn during amniocentesis at weeks 16 - 23 of gestation have a positive, stable staining effect on the AL-SENSE panty liner. Hence, AL-SENSE may be reliable for detection of amniotic fluid leakage during the second trimester.

关 键 词:Panty LINER AMNIOCENTESIS SECOND Trimester PREMATURE RUPTURE of Membranes 

分 类 号:R73[医药卫生—肿瘤]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象