Image Application in Single Isocenter Multiple Target SRS  

Image Application in Single Isocenter Multiple Target SRS

在线阅读下载全文

作  者:Junfang Gao Jeffrey P. Limmer Junfang Gao;Jeffrey P. Limmer(Radiation Oncology Department, Texas Oncology, Houston, TX, USA)

机构地区:[1]Radiation Oncology Department, Texas Oncology, Houston, TX, USA

出  处:《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》2024年第2期27-40,共14页医学物理学、临床工程、放射肿瘤学(英文)

摘  要:Single isocenter multiple target stereotactic radiosurgery (SIMT-SRS) has potentially emerged as a new pillar in radio-immune combination therapy for the management of brain metastasis. Accuracy and efficiency are pushed to a higher level in the era of the linear accelerator-based SIMT-SRS. This short review focuses on patient selection, image preparation, patient simulation, electronic portal imaging device (EPID) QA, and the patient treatment process in the SIMT-SRS treatment only. Image-relevant recommendations and guidelines are presented and contrast application, acquisition efficiency, and alignment accuracy of CT and MRI images are explored. With guidance, the SIMT-SRS can be implemented with high precision and efficiency. 1 mm or 0.5 mm and non-uniform PTV margin expansion for all targets would become possible. It will enhance cancer killing effect in radio-immune combination therapy. General routine daily, monthly, and annual linear accelerator image quality assurances are excluded.Single isocenter multiple target stereotactic radiosurgery (SIMT-SRS) has potentially emerged as a new pillar in radio-immune combination therapy for the management of brain metastasis. Accuracy and efficiency are pushed to a higher level in the era of the linear accelerator-based SIMT-SRS. This short review focuses on patient selection, image preparation, patient simulation, electronic portal imaging device (EPID) QA, and the patient treatment process in the SIMT-SRS treatment only. Image-relevant recommendations and guidelines are presented and contrast application, acquisition efficiency, and alignment accuracy of CT and MRI images are explored. With guidance, the SIMT-SRS can be implemented with high precision and efficiency. 1 mm or 0.5 mm and non-uniform PTV margin expansion for all targets would become possible. It will enhance cancer killing effect in radio-immune combination therapy. General routine daily, monthly, and annual linear accelerator image quality assurances are excluded.

关 键 词:SIMT-SRS Image Application 

分 类 号:R73[医药卫生—肿瘤]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象