Inter-Fraction Analysis of One Week Hypo-Fractionation of Deep Inspiration Breath Hold (DIBH) Technique for Left Sided Breast Cancer Radiation Treatment  

Inter-Fraction Analysis of One Week Hypo-Fractionation of Deep Inspiration Breath Hold (DIBH) Technique for Left Sided Breast Cancer Radiation Treatment

在线阅读下载全文

作  者:Ntombela N. Lethukuthula Mathuthu Manny Nyathi Mpumelelo Ntombela N. Lethukuthula;Mathuthu Manny;Nyathi Mpumelelo(Centre for Applied Radiation and Technology (CARST), North West University, Mahikeng, South Africa;Department of Medical Physics, Sefako Makgatho Health Sciences University, Ga-Rankuwa, South Africa)

机构地区:[1]Centre for Applied Radiation and Technology (CARST), North West University, Mahikeng, South Africa [2]Department of Medical Physics, Sefako Makgatho Health Sciences University, Ga-Rankuwa, South Africa

出  处:《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》2024年第3期41-52,共12页医学物理学、临床工程、放射肿瘤学(英文)

摘  要:The aim of this study was to investigate the inter-fraction variations, patient comfort and knowledge at Charlotte Maxeke Johannesburg Academic Hospital (CMJAH). The differences in set-up that occurred between treatment sessions for the left sided breast patients were observed and recorded. Measurements of routine set-up variation for 24 patients were performed by matching the cone beam computed tomography (CBCT) and the planning computed tomography (CT). Scans of all five fractions per patient were used to quantify the setup variations with standard deviation (SD) in all the three directions (anterior posterior, left right, and superior inferior). The patients DIBH comfort and knowledge was also evaluated. The average translational errors for the anterior posterior (AP, z), left-right (LR, x), and Superior-inferior (SI, y) directions were 0.40 cm, 0.40 cm, and 0.40 cm, respectively. The translation variation of the three directions showed statistical significance (P < 0.05). On comfort and knowledge investigation, among all participants, 80% moderately agreed that the therapist’s instructions for operating the deep inspiration breath hold (DIBH) technique were easy to understand, and 63.33% indicated that their comfort with the DIBH technique was neutral or average. The inter-fraction variations in patients with left-sided breast cancer were qualitatively analyzed. Significant shifts between CBCT and planning CT images were observed. The daily treatment verification could assist accurate dose delivery.The aim of this study was to investigate the inter-fraction variations, patient comfort and knowledge at Charlotte Maxeke Johannesburg Academic Hospital (CMJAH). The differences in set-up that occurred between treatment sessions for the left sided breast patients were observed and recorded. Measurements of routine set-up variation for 24 patients were performed by matching the cone beam computed tomography (CBCT) and the planning computed tomography (CT). Scans of all five fractions per patient were used to quantify the setup variations with standard deviation (SD) in all the three directions (anterior posterior, left right, and superior inferior). The patients DIBH comfort and knowledge was also evaluated. The average translational errors for the anterior posterior (AP, z), left-right (LR, x), and Superior-inferior (SI, y) directions were 0.40 cm, 0.40 cm, and 0.40 cm, respectively. The translation variation of the three directions showed statistical significance (P < 0.05). On comfort and knowledge investigation, among all participants, 80% moderately agreed that the therapist’s instructions for operating the deep inspiration breath hold (DIBH) technique were easy to understand, and 63.33% indicated that their comfort with the DIBH technique was neutral or average. The inter-fraction variations in patients with left-sided breast cancer were qualitatively analyzed. Significant shifts between CBCT and planning CT images were observed. The daily treatment verification could assist accurate dose delivery.

关 键 词:Breast Cancer Deep Inspiration Breath Hold Hypo-Fractionation Inter-Fraction 

分 类 号:R73[医药卫生—肿瘤]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象