检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Kenji D. Furukawa Naoto Yamaaki Aya Fujimoto Kiminori Ohyama Hiroaki Muramoto Kenji D. Furukawa;Naoto Yamaaki;Aya Fujimoto;Kiminori Ohyama;Hiroaki Muramoto(Department of Internal Medicine, Japan Community Health care Organization (JCHO) Kanazawa Hospital, Kanazawa, Japan)
出 处:《Journal of Diabetes Mellitus》2016年第3期197-203,共7页糖尿病(英文)
摘 要:We implemented a 3-3-1 algorithm in order to provide safe and simple self-titration in patients who newly initiated BOT as well as who were already on BOT and evaluated its utility in clinical setting. A total of 46 patients, 21 patients in the newly-initiated group and 25 patients in the existing BOT group performed dose adjustment using 3-3-1 algorithm. HbA1c was significantly improved 4 weeks after the initiation from 8.5% ± 1.2% at baseline to 7.3% ± 0.7% at the final evaluation (p 0.01, vs. Baseline). The average daily insulin units increased throughout the study period from 10.1 ± 6.7 at baseline to 14.6 ± 8.9 units at the final evaluation. Weight didn’t significantly change throughout the study (p = 0.12). The incidents of hypoglycemia were 0.8/month during the insulin dose self-adjustment period and 0.4/month during the follow-up period. The 3-3-1 algorithm using insulin glargine provided a safe and simple dose adjustment and demonstrated its utility in patients who were newly introduced to insulin treatment as well as who were already on BOT.We implemented a 3-3-1 algorithm in order to provide safe and simple self-titration in patients who newly initiated BOT as well as who were already on BOT and evaluated its utility in clinical setting. A total of 46 patients, 21 patients in the newly-initiated group and 25 patients in the existing BOT group performed dose adjustment using 3-3-1 algorithm. HbA1c was significantly improved 4 weeks after the initiation from 8.5% ± 1.2% at baseline to 7.3% ± 0.7% at the final evaluation (p 0.01, vs. Baseline). The average daily insulin units increased throughout the study period from 10.1 ± 6.7 at baseline to 14.6 ± 8.9 units at the final evaluation. Weight didn’t significantly change throughout the study (p = 0.12). The incidents of hypoglycemia were 0.8/month during the insulin dose self-adjustment period and 0.4/month during the follow-up period. The 3-3-1 algorithm using insulin glargine provided a safe and simple dose adjustment and demonstrated its utility in patients who were newly introduced to insulin treatment as well as who were already on BOT.
关 键 词:GLARGINE Self-Titration BOT T2DM INSULIN 3-3-1 Algorithm
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.145.49.32