Lymphoscintigraphy Using Dynamic Imaging and SPECT/CT in Chylothorax  

Lymphoscintigraphy Using Dynamic Imaging and SPECT/CT in Chylothorax

在线阅读下载全文

作  者:Asami Ohtsuka Yusuke Inoue Yuji Asano Reiko Woodhams Kazu Shiomi 

机构地区:[1]Department of Diagnostic Radiology, Kitasato University School of Medicine, Sagamihara, Japan [2]Department of Thoracic Surgery, Kitasato University School of Medicine, Sagamihara, Japan

出  处:《Open Journal of Medical Imaging》2013年第3期86-89,共4页医学影像期刊(英文)

摘  要:Lymphoscintigraphy readily provides confirmation of chylothorax but not detailed localization of the leakage site. A 77-year-old woman developed traumatic chylothorax and underwent lymphoscintigraphy with radiolabeled albumin to identify the site of lymph leakage. Dynamic imaging demonstrated appearance of focal activity presumably in the upper mediastinum, followed by spread to the left hemithorax. Subsequently, SPECT/CT showed that the leakage site was located in the left side of the upper mediastinum, and this location was confirmed during video-assisted thoracoscopic surgery. Dynamic imaging demonstrated the site of first appearance of abnormal activity, and SPECT/CT enabled detailed localization of the abnormal activity with anatomic correlation. The combination of dynamic imaging with SPECT/CT appears to be recommendable for lymphoscintigraphic assessment of chylothorax.Lymphoscintigraphy readily provides confirmation of chylothorax but not detailed localization of the leakage site. A 77-year-old woman developed traumatic chylothorax and underwent lymphoscintigraphy with radiolabeled albumin to identify the site of lymph leakage. Dynamic imaging demonstrated appearance of focal activity presumably in the upper mediastinum, followed by spread to the left hemithorax. Subsequently, SPECT/CT showed that the leakage site was located in the left side of the upper mediastinum, and this location was confirmed during video-assisted thoracoscopic surgery. Dynamic imaging demonstrated the site of first appearance of abnormal activity, and SPECT/CT enabled detailed localization of the abnormal activity with anatomic correlation. The combination of dynamic imaging with SPECT/CT appears to be recommendable for lymphoscintigraphic assessment of chylothorax.

关 键 词:CHYLOTHORAX LYMPHOSCINTIGRAPHY 99mTc-DTPA-HSA DYNAMIC IMAGING SPECT/CT 

分 类 号:R73[医药卫生—肿瘤]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象