检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Valentin T. Diaz-Aleman Marta Gonzalez-Hernandez Denisse Angel-Pereira Andres Blasco-Alberto Valentin T. Diaz-Aleman;Marta Gonzalez-Hernandez;Denisse Angel-Pereira;Andres Blasco-Alberto(Department of Ophthalmology, Hospital Universitario de Canarias, S/C de Tenerife, Spain)
机构地区:[1]Department of Ophthalmology, Hospital Universitario de Canarias, S/C de Tenerife, Spain
出 处:《Open Journal of Ophthalmology》2016年第3期150-157,共9页眼科学期刊(英文)
摘 要:Purpose: The main objective was to analyze the relationship between maximum cup depth (MCD), mean defect (MD), central corneal thickness (CCT), age and disc area, in patients with ocular hypertension (OHT) and primary open angle glaucoma (POAG). Methods: Cross-sectional study of patients diagnosed with OHT and POAG. Visual fields were obtained using an Octopus 300 analyzer, TOP strategy. MCD and disc area were obtained using a Heidelberg Retina Tomograph. Results: The study sample comprised 234 eyes of 143 patients, 91 women and 52 men, mean age 63.55 years (SD 10.49). Mean values were: MCD 0.52 mm (SD 0.27), MD 2.78 dB (SD 5.02), CCT 543.5 μm (SD 36.63), IOP 16.73 mmHg (SD 2.93), and disc area 2.01 mm<sup>2</sup> (SD 0.39). A significant correlation was observed between MCD and age in patients under 60 years, between MCD and disc area, and between MD and disc area. Conclusions: Our study showed a correlation between MCD and age which was significant in patients under 60 years of age, between MCD and disc area and between MD and disc area, suggesting that the larger the disc area, the greater the MCD and the MD in patients with OHT and POAG.Purpose: The main objective was to analyze the relationship between maximum cup depth (MCD), mean defect (MD), central corneal thickness (CCT), age and disc area, in patients with ocular hypertension (OHT) and primary open angle glaucoma (POAG). Methods: Cross-sectional study of patients diagnosed with OHT and POAG. Visual fields were obtained using an Octopus 300 analyzer, TOP strategy. MCD and disc area were obtained using a Heidelberg Retina Tomograph. Results: The study sample comprised 234 eyes of 143 patients, 91 women and 52 men, mean age 63.55 years (SD 10.49). Mean values were: MCD 0.52 mm (SD 0.27), MD 2.78 dB (SD 5.02), CCT 543.5 μm (SD 36.63), IOP 16.73 mmHg (SD 2.93), and disc area 2.01 mm<sup>2</sup> (SD 0.39). A significant correlation was observed between MCD and age in patients under 60 years, between MCD and disc area, and between MD and disc area. Conclusions: Our study showed a correlation between MCD and age which was significant in patients under 60 years of age, between MCD and disc area and between MD and disc area, suggesting that the larger the disc area, the greater the MCD and the MD in patients with OHT and POAG.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.117