Three-Dimensional Finite Elemental Analysis of Bone Stress near an Implant Placed at the Border between Mandible and Fibular Graft in Mandibular Reconstruction  

Three-Dimensional Finite Elemental Analysis of Bone Stress near an Implant Placed at the Border between Mandible and Fibular Graft in Mandibular Reconstruction

在线阅读下载全文

作  者:Yukawa Ken Tachikawa Noriko Kasugai Shohei 

机构地区:[1]Oral Implantology and Regenerative Dental Medicine, Department of Masticatory Function Rehabilitation, Tokyo Medical and Dental University, Tokyo, Japan

出  处:《Open Journal of Regenerative Medicine》2015年第4期35-45,共11页再生医学期刊(英文)

摘  要:Purpose: The aim of the present study was to use finite elemental analysis (FEA) to evaluate bone stress near an implant placed at the border between the mandible and fibular graft in mandibular reconstruction. Materials and Methods: A fibular model (FM) and transplantation model (TM) were constructed for FEA. In TM, mandible was on the mesial side and the fibular graft was on the distal side. The implant was positioned at the center of both bone models. In TM, it was placed on the border between the mandible and fibular graft. A 10-mm implant was used in the monocortical model and a 15-mm implant was used in the bicortical model. The loading force was set at 100 N, the angle was set at 90°, and the loading position was set as center, mesial, or distal on the upper surface of the prosthesis. Von Mises equivalent stress values of the bone near the implant collar and apex at the middle line between buccal and lingual side were measured. Results: In all models, stress values were significantly lower with center loading than with distal loading and mesial loading. In center loading, the stress values were significantly lower in the bicortical model than in the monocortical model. There were no significant differences in stress values between FM and TM in all conditions. Conclusions: Bone stress was least with the center loading position, which was further decreased by bicortical fixation. There was no increase in mechanical stress associated with placing an implant at the border between the mandible and the fibular graft.Purpose: The aim of the present study was to use finite elemental analysis (FEA) to evaluate bone stress near an implant placed at the border between the mandible and fibular graft in mandibular reconstruction. Materials and Methods: A fibular model (FM) and transplantation model (TM) were constructed for FEA. In TM, mandible was on the mesial side and the fibular graft was on the distal side. The implant was positioned at the center of both bone models. In TM, it was placed on the border between the mandible and fibular graft. A 10-mm implant was used in the monocortical model and a 15-mm implant was used in the bicortical model. The loading force was set at 100 N, the angle was set at 90°, and the loading position was set as center, mesial, or distal on the upper surface of the prosthesis. Von Mises equivalent stress values of the bone near the implant collar and apex at the middle line between buccal and lingual side were measured. Results: In all models, stress values were significantly lower with center loading than with distal loading and mesial loading. In center loading, the stress values were significantly lower in the bicortical model than in the monocortical model. There were no significant differences in stress values between FM and TM in all conditions. Conclusions: Bone stress was least with the center loading position, which was further decreased by bicortical fixation. There was no increase in mechanical stress associated with placing an implant at the border between the mandible and the fibular graft.

关 键 词:Finite Elemental ANALYSIS MANDIBULAR Reconstruction FIBULAR Graft Dental IMPLANT Stress ANALYSIS 

分 类 号:R73[医药卫生—肿瘤]

 