检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Kenneth R. Hassler Kaveh Homayoon
机构地区:[1]Department of Surgery, Maricopa Integrated Health System, Phoenix, USA [2]Department of Surgery—Urology Division, Maricopa Integrated Health System, Phoenix, USA
出 处:《Open Journal of Urology》2018年第8期223-227,共5页泌尿学期刊(英文)
摘 要:Background: There were 800 individual case reports of urogenital foreign bodies in the English literature from 1755 to 1999. The use of urogenital foreign bodies for sexual pleasure is a common occurrence in today’s population. The aim of this discussion is the management of scrotal injury caused by magnetic urogenital foreign bodies. Case Presentation: 56-year-old male with scrotal tissue entrapped between two opposed magnet rings. Self-reported attempts at removal were unsuccessful and caused for presentation to the emergency department. Additional attempts at removal by medical staff unsuccessful in emergency department and therefore the patient proceeded to the operating room. Intraoperatively the use of two cardiac magnets allowed for removal without a need for invasive surgical procedure. Conclusion: Cardiac magnets are preferred means of removal for entrapped skin between magnetic foreign bodies that could be utilized at the bedside.Background: There were 800 individual case reports of urogenital foreign bodies in the English literature from 1755 to 1999. The use of urogenital foreign bodies for sexual pleasure is a common occurrence in today’s population. The aim of this discussion is the management of scrotal injury caused by magnetic urogenital foreign bodies. Case Presentation: 56-year-old male with scrotal tissue entrapped between two opposed magnet rings. Self-reported attempts at removal were unsuccessful and caused for presentation to the emergency department. Additional attempts at removal by medical staff unsuccessful in emergency department and therefore the patient proceeded to the operating room. Intraoperatively the use of two cardiac magnets allowed for removal without a need for invasive surgical procedure. Conclusion: Cardiac magnets are preferred means of removal for entrapped skin between magnetic foreign bodies that could be utilized at the bedside.
关 键 词:UROGENITAL FOREIGN BODY MAGNET MAGNETIC SCROTAL Scrotum UROGENITAL MAGNETIC FOREIGN BODY SCROTAL Magnets MAGNETIC FOREIGN BODY UROGENITAL MAGNET Removal SCROTAL MAGNET Removal
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.222