Storage of Gamma-Glutamyltransferase from Dried Serum Spots: Matrix for Field Based Studies  

Storage of Gamma-Glutamyltransferase from Dried Serum Spots: Matrix for Field Based Studies

在线阅读下载全文

作  者:Ram Kumar Rizwana Quraishi Ram Kumar;Rizwana Quraishi(National Drug Dependence Treatment Center, All India Institute of Medical Sciences, New Delhi, India)

机构地区:[1]National Drug Dependence Treatment Center, All India Institute of Medical Sciences, New Delhi, India

出  处:《Pharmacology & Pharmacy》2023年第11期478-481,共4页药理与制药(英文)

摘  要:Background: Gamma-glutamyltransferase is recognised as a biomarker to assess the harms associated with alcohol misuse. The objective ways to measure GGT in areas lacking central lab facilities are desirable. This study aims to measure GGT from dried serum spots and its storage from dried serum spots. Method: The study was approved by the institutional ethical committee. One hundred and eighty (180) patients were included in the study. Their blood samples were collected. The serum samples were spotted onto filter paper (Whatman 903) dried and stored at 4°C. The GGT levels were measured on the day of collection and at various time periods to assess the effect of storage. All the analysis was performed on SPSS version 21. Result: The GGT levels measured from fresh serum GGT levels mean (SD) 286.5 (539.4) correlated well with their respective dried serum levels 287.18 (538.2) (P = 0.80). The mean recovery of GGT from dried serum was observed to be 103.3%. A sub-sample (n = 12) was stored at 4°C. The dried serum spots were found to be stable at the end of four weeks using repeated measure analysis of variance (ANOVA) (P = 0.39). Conclusion: This method has the potential to be used for epidemiological or field based studies to assess harms associated with alcohol use.Background: Gamma-glutamyltransferase is recognised as a biomarker to assess the harms associated with alcohol misuse. The objective ways to measure GGT in areas lacking central lab facilities are desirable. This study aims to measure GGT from dried serum spots and its storage from dried serum spots. Method: The study was approved by the institutional ethical committee. One hundred and eighty (180) patients were included in the study. Their blood samples were collected. The serum samples were spotted onto filter paper (Whatman 903) dried and stored at 4°C. The GGT levels were measured on the day of collection and at various time periods to assess the effect of storage. All the analysis was performed on SPSS version 21. Result: The GGT levels measured from fresh serum GGT levels mean (SD) 286.5 (539.4) correlated well with their respective dried serum levels 287.18 (538.2) (P = 0.80). The mean recovery of GGT from dried serum was observed to be 103.3%. A sub-sample (n = 12) was stored at 4°C. The dried serum spots were found to be stable at the end of four weeks using repeated measure analysis of variance (ANOVA) (P = 0.39). Conclusion: This method has the potential to be used for epidemiological or field based studies to assess harms associated with alcohol use.

关 键 词:STORAGE GAMMA-GLUTAMYLTRANSFERASE Dried Serum Spots 

分 类 号:R57[医药卫生—消化系统]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象