Surgical Method for Facilitation of Aortic Valve Replacement:Intraoperative Application of External Pressure for Increasing the Transverse Axis of Aortic Annulus  

在线阅读下载全文

作  者:Sahin Bozok Mert Kestelli Aykut Sahin Hakan Kara Tevfik Günes Berkan Ozpak Gokhan Ilhan Serdar Bayrak 

机构地区:[1]Department of Cardiovascular Surgery,Recep Tayyip Erdogan University Faculty of Medicine,Training and Research Hospital,Rize,Turkey [2]Department of Cardiovascular Surgery,Izmir Katip Celebi University Faculty of Medicine,Atatürk Training and Research Hospital,Izmir,Turkey [3]Department of Cardiovascular Surgery,Osmangazi University Faculty of Medicine,Eskisehir,Turkey [4]Department of Cardiovascular Surgery,Ada Hospital,Giresun,Turkey [5]Department of Cardiovascular Surgery,Pamukkale University Faculty of Medicine,Denizli,Turkey

出  处:《World Journal of Cardiovascular Surgery》2015年第10期108-113,共6页心血管外科国际期刊(英文)

摘  要:Background: Surgical method was introduced for enhancement of prosthetic valve insertion and overcoming difficulties ensourcing from prosthesis-patient mismatch. Methods: Twenty-two patients that underwent aortic valve replacement between January 2005 and July 2009 were included in this prospective study. In these patients, the insertion of prosthesis larger than the annulus diameter was attempted after the application of an external pressure that increased the transverse axis diameter of the aortic annulus. The postoperative results and complications were assessed. Results: This surgical method was performed on 22 patients (16 males, 6 females, mean age: 52.2 ± 15.8 years) during the valve replacement. In 12 patients (55%), replacement of proper sized aortic valve compliant to their surface area was accomplished, while the insertion of a proper valve could not be achieved in 10 (45%) of the patients. No perioperative mortality or complications related to the procedure were reported. Conclusion: Increasing the transverse diameter of aortic valve may not only facilitate the insertion of a prosthetic valve but also aid in overcoming prosthesis-patient mismatch. Further studies on larger series are necessary to document the actual effectively and precise selection criteria for application of this method.Background: Surgical method was introduced for enhancement of prosthetic valve insertion and overcoming difficulties ensourcing from prosthesis-patient mismatch. Methods: Twenty-two patients that underwent aortic valve replacement between January 2005 and July 2009 were included in this prospective study. In these patients, the insertion of prosthesis larger than the annulus diameter was attempted after the application of an external pressure that increased the transverse axis diameter of the aortic annulus. The postoperative results and complications were assessed. Results: This surgical method was performed on 22 patients (16 males, 6 females, mean age: 52.2 ± 15.8 years) during the valve replacement. In 12 patients (55%), replacement of proper sized aortic valve compliant to their surface area was accomplished, while the insertion of a proper valve could not be achieved in 10 (45%) of the patients. No perioperative mortality or complications related to the procedure were reported. Conclusion: Increasing the transverse diameter of aortic valve may not only facilitate the insertion of a prosthetic valve but also aid in overcoming prosthesis-patient mismatch. Further studies on larger series are necessary to document the actual effectively and precise selection criteria for application of this method.

关 键 词:Aortic Valve REPLACEMENT PROSTHESIS MISMATCH Aortic Annulus 

分 类 号:R73[医药卫生—肿瘤]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象