Studying of Common Factors Affecting Reading of Lithium Fluoride Thermo-Luminescence Dosimeter Crystal  

Studying of Common Factors Affecting Reading of Lithium Fluoride Thermo-Luminescence Dosimeter Crystal

在线阅读下载全文

作  者:Mohammed A. Ali Omer Abdulrahman A. Alsayyari Jumaa Y. Tamboul Rowida B. Ali Amira A. Ahmed Ahmed Abukonna 

机构地区:[1]Department of Radiologic Technology, College of Applied Medical Science, Qassim University, Buraidah, KSA [2]Department of Radiotherapy, College of Medical Radiologic Science, Sudan University of Science & Technology, Khartoum, Sudan [3]Department of Diagnostic Radiologic Technology, College of Applied Medical Sciences, Taibah University, Medina, KSA [4]Department of Radiation Safeties, Sudan Atomic Energy Commission, Khartoum, Sudan

出  处:《Open Journal of Biophysics》2017年第1期14-24,共11页生物物理学期刊(英文)

摘  要:The aim of this study was to study the technical factors affecting the reading of TLD (LiF:Mg:Ti) for radiation dosimetry. The method adapted was an exposure of LiF:Mg:Ti crystal with?γ-ray with the following filters (Hp 0.07 and Hp?10), before and after usage of filter Hp?(0.07), annealing, cooling by nitrogen flux and crystal morphology by scanning electron microscope. The collected data analyzed by EXCELL software showed that: TLD average count/second (C/s) with filter Hp?(10) was greater than that obtained with filter Hp?(0.07) with an amount of 1191 c/s?(19%). Also the analysis showed that: the average C/s without filter Hp?(0.07) was greater than that with filter by an amount of 994.5 C/s (16.4%), and there was proportional linear relationship;as the applied dose increased the TLD C/s increased significantly (R2?=?0.9) based on the equations: y = 885.1x???286.5 and y = 860.5x?+ 856.8 for filtered and without filtered beam respectively, where?x?refers to applied dose in mGy and?y?refers to C/s. Also the average C/s without nitrogen flux (cooling) was greater than with nitrogen count with an amount of 52.4 C/s (11%). The annealing (without filter) causes a reduction in dose by 82.2?μGy (19.2%), and in case of annealing with filter, the dose reduced by 66.7?μGy (21.9%) relative to annealing without filter. The morphology of TLD crystal shown by scanning electron microscope SEM was a darkening surface after irradiation.The aim of this study was to study the technical factors affecting the reading of TLD (LiF:Mg:Ti) for radiation dosimetry. The method adapted was an exposure of LiF:Mg:Ti crystal with?γ-ray with the following filters (Hp 0.07 and Hp?10), before and after usage of filter Hp?(0.07), annealing, cooling by nitrogen flux and crystal morphology by scanning electron microscope. The collected data analyzed by EXCELL software showed that: TLD average count/second (C/s) with filter Hp?(10) was greater than that obtained with filter Hp?(0.07) with an amount of 1191 c/s?(19%). Also the analysis showed that: the average C/s without filter Hp?(0.07) was greater than that with filter by an amount of 994.5 C/s (16.4%), and there was proportional linear relationship;as the applied dose increased the TLD C/s increased significantly (R2?=?0.9) based on the equations: y = 885.1x???286.5 and y = 860.5x?+ 856.8 for filtered and without filtered beam respectively, where?x?refers to applied dose in mGy and?y?refers to C/s. Also the average C/s without nitrogen flux (cooling) was greater than with nitrogen count with an amount of 52.4 C/s (11%). The annealing (without filter) causes a reduction in dose by 82.2?μGy (19.2%), and in case of annealing with filter, the dose reduced by 66.7?μGy (21.9%) relative to annealing without filter. The morphology of TLD crystal shown by scanning electron microscope SEM was a darkening surface after irradiation.

关 键 词:Radiation Effects DOSIMETER Factors THERMOLUMINESCENCE 

分 类 号:R73[医药卫生—肿瘤]

 