检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Yan Jia Can Wang Zehui Chang Wenxiong Li Chi Zhang
出 处:《Open Journal of Fluid Dynamics》2017年第3期426-447,共22页流体动力学(英文)
摘 要:Plate heat exchanger can obtain higher thermal performance because of its advantages in high heat transfer coefficient, small scale, and can realize pure counter current flow. It has been widely applied in HVAC industry. In this paper, the numerical research of plate heat exchanger in solar heating system has been proposed. Aimed at the type of herringbone corrugated plate which has better thermal performance and been widely used, the three dimensional model is established by Gambit software. Using FLUENT software for numerical calculation, by studying the effect of corrugated inclination angle, corrugated depth, corrugated spacing and inlet velocity of heat exchanger on internal temperature, pressure, velocity distributions of domains, the relationship between the above parameters and the Nusselt Number and the pressure drop was obtained by simulation data. Heat transfer coefficient and pressure drop correlations used to measure the overall performance of the heat exchanger. The result shows that the optimal structure parameters is corrugated angle 60°, corrugated depth 4 mm and corrugated spacing 16 mm.Plate heat exchanger can obtain higher thermal performance because of its advantages in high heat transfer coefficient, small scale, and can realize pure counter current flow. It has been widely applied in HVAC industry. In this paper, the numerical research of plate heat exchanger in solar heating system has been proposed. Aimed at the type of herringbone corrugated plate which has better thermal performance and been widely used, the three dimensional model is established by Gambit software. Using FLUENT software for numerical calculation, by studying the effect of corrugated inclination angle, corrugated depth, corrugated spacing and inlet velocity of heat exchanger on internal temperature, pressure, velocity distributions of domains, the relationship between the above parameters and the Nusselt Number and the pressure drop was obtained by simulation data. Heat transfer coefficient and pressure drop correlations used to measure the overall performance of the heat exchanger. The result shows that the optimal structure parameters is corrugated angle 60°, corrugated depth 4 mm and corrugated spacing 16 mm.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.33