Patient’s Comfort and Technical Quality Exams at 1.5 and 3.0 T Magnetic Resonance Imaging  

Patient’s Comfort and Technical Quality Exams at 1.5 and 3.0 T Magnetic Resonance Imaging

在线阅读下载全文

作  者:Siniša Vujmilović Saša Vujnović Violeta Kovačević-Dragosavljević Zoran Vujković Davorka Katana Dragana Grujić-Vujmilović Siniša Vujmilović;Saša Vujnović;Violeta Kovačević-Dragosavljević;Zoran Vujković;Davorka Katana;Dragana Grujić-Vujmilović(Institute of Clinical Radiology, University Clinical Centre of the Republic of Srpska, Bosnia and Herzegovina, Banjaluka, Bosnia and Herzegovina;Clinic of Neurology, University Clinical Centre of the Republic of Srpska, Bosnia and Herzegovina, Banjaluka, Bosnia and Herzegovina;Public Health Institute of the Republic of Srpska, Department of Social Medicine, Medical Faculty of Banjaluka University, Bosnia and Herzegovina, Banjaluka, Bosnia and Herzegovina)

机构地区:[1]Institute of Clinical Radiology, University Clinical Centre of the Republic of Srpska, Bosnia and Herzegovina, Banjaluka, Bosnia and Herzegovina [2]Clinic of Neurology, University Clinical Centre of the Republic of Srpska, Bosnia and Herzegovina, Banjaluka, Bosnia and Herzegovina [3]Public Health Institute of the Republic of Srpska, Department of Social Medicine, Medical Faculty of Banjaluka University, Bosnia and Herzegovina, Banjaluka, Bosnia and Herzegovina

出  处:《Open Journal of Radiology》2016年第4期264-274,共11页放射学期刊(英文)

摘  要:Increased interest of clinicians for using 3.0 T magnetic resonance imaging (MRI), as imaging modality of choice for their patients, has been evident in the past few years. The aim of this study was to compare the technical quality of the obtained tomography using 3.0 T and 1.5 T MRI, and to compare the subjective feeling of discomfort of patients and subjective acoustic noise experience during imaging using MRI at 3.0 T and 1.5 T. Brain MRI (1.5 and 3.0 T) was performed in 58 patients, according to a standardized protocol. All studies have been randomly described by independent two radiologists. The reference standard for the existence of technical artifact is established on the basis of both radiologists’ consensus. We also compared the subjective feelings of the discomfort and acoustic noise during the both MRI (1.5 T and 3.0 T) exams. Artifacts were significantly more common during 3.0 T MRI in comparison with the 1.5 T MRI (χ2 = 5.286, P < 0.05), as well as in male patients (χ2 = 8.841, P < 0.05), and sub-jective assessments of discomfort and acoustic noise were higher in patients who underwent imaging using 3.0 T MRI, (χ2 = 125.959, df = 1, P < 0.001) and in females (χ2 = 195.449, df = 1, P < 0.001). Additional research is needed to prove that appropriate information for patients about the discomfort during 3.0 T MRI and their psychological preparation is very important element for optimal use of 3.0 T MRI in daily clinical practice.Increased interest of clinicians for using 3.0 T magnetic resonance imaging (MRI), as imaging modality of choice for their patients, has been evident in the past few years. The aim of this study was to compare the technical quality of the obtained tomography using 3.0 T and 1.5 T MRI, and to compare the subjective feeling of discomfort of patients and subjective acoustic noise experience during imaging using MRI at 3.0 T and 1.5 T. Brain MRI (1.5 and 3.0 T) was performed in 58 patients, according to a standardized protocol. All studies have been randomly described by independent two radiologists. The reference standard for the existence of technical artifact is established on the basis of both radiologists’ consensus. We also compared the subjective feelings of the discomfort and acoustic noise during the both MRI (1.5 T and 3.0 T) exams. Artifacts were significantly more common during 3.0 T MRI in comparison with the 1.5 T MRI (χ2 = 5.286, P < 0.05), as well as in male patients (χ2 = 8.841, P < 0.05), and sub-jective assessments of discomfort and acoustic noise were higher in patients who underwent imaging using 3.0 T MRI, (χ2 = 125.959, df = 1, P < 0.001) and in females (χ2 = 195.449, df = 1, P < 0.001). Additional research is needed to prove that appropriate information for patients about the discomfort during 3.0 T MRI and their psychological preparation is very important element for optimal use of 3.0 T MRI in daily clinical practice.

关 键 词:Magnetic Resonance Imaging (MRI) 3.0 T ARTIFACTS Acoustic Noise DISCOMFORT COMFORT 