检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Sophie Edouard Carine Couderc Didier Raoult Pierre-Edouard Fournier
机构地区:[1]Unite de Recherche sur les Maladies Infectieuses Tropicales et Emergentes(URMITE),Aix-Marseille Universite,Marseille,France [2]Federation de Microbiologie Clinique,Hopital de la Timone,Marseille,France
出 处:《Advances in Microbiology》2012年第4期497-504,共8页微生物学(英文)
摘 要:Propionibacterium species are mostly environmental bacteria, some being commensal of mammals including humans, and sometimes pathogenic. These bacteria are poorly identified using routine laboratory methods. Recently, Matrix Assisted Laser Desorption Ionization Time-of-Flight Mass Spectrometry (MALDI-TOF-MS) has emerged as a rapid and efficient method to identify bacterial species. We evaluated the use of MALDI-TOF-MS for identification of all validated Propionibacterium species. Only four of the 15 tested reference strains (26.7%) were correctly identified at the species level, and P. acnes, the most common human pathogenic species was not identified. When applying MALDI-TOF-MS to 48 P. acnes strains, only 18.7% were correctly identified, suggesting an intraspecific variability of proteic profiles among Propionibacterium strains. However, by enriching the Bruker database with spectra from five of these strains and re-testing the other 43 strains against this new database, 93.0% were correctly identified. Our study demonstrates that MALDI-TOF-MS may be used for the identification of Propionibacterium isolates but requires a database enrichment in spectra from additional isolates.Propionibacterium species are mostly environmental bacteria, some being commensal of mammals including humans, and sometimes pathogenic. These bacteria are poorly identified using routine laboratory methods. Recently, Matrix Assisted Laser Desorption Ionization Time-of-Flight Mass Spectrometry (MALDI-TOF-MS) has emerged as a rapid and efficient method to identify bacterial species. We evaluated the use of MALDI-TOF-MS for identification of all validated Propionibacterium species. Only four of the 15 tested reference strains (26.7%) were correctly identified at the species level, and P. acnes, the most common human pathogenic species was not identified. When applying MALDI-TOF-MS to 48 P. acnes strains, only 18.7% were correctly identified, suggesting an intraspecific variability of proteic profiles among Propionibacterium strains. However, by enriching the Bruker database with spectra from five of these strains and re-testing the other 43 strains against this new database, 93.0% were correctly identified. Our study demonstrates that MALDI-TOF-MS may be used for the identification of Propionibacterium isolates but requires a database enrichment in spectra from additional isolates.
关 键 词:PROPIONIBACTERIUM Propionibacterium acnes MALDI-TOF Mass Spectrometry
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.22.98.193