Electrolyzed Oxidized Water (EOW): Non-Thermal Approach for Decontamination of Food Borne Microorganisms in Food Industry  

Electrolyzed Oxidized Water (EOW): Non-Thermal Approach for Decontamination of Food Borne Microorganisms in Food Industry

在线阅读下载全文

作  者:Subrota Hati Surajit Mandal P. S. Minz Shilpa Vij Yogesh Khetra B. P. Singh Dipika Yadav 

机构地区:[1]Dairy Engineering Division, National Dairy Research Institute, Deemed University, Karnal, India [2]Dairy Microbiology Division, National Dairy Research Institute, Deemed University, Karnal, India [3]Dairy Technology Division, National Dairy Research Institute, Deemed University, Karnal, India.

出  处:《Food and Nutrition Sciences》2012年第6期760-768,共9页食品与营养科学(英文)

摘  要:Electrolyzed Oxidized Water (EOW) is produced by passing a diluted salt solution through an electrolytic cell, having anode and cathode electrodes. The anode and cathode are separated by a bipolar membrane. Negatively charged ions—chloride and hydroxide in the diluted salt solution move to anode to give up electrons and become gas (O2, Cl2) and hypochlorous acid and having redox potential of +700 to +800 mV with pH 4.0. It has a strong oxidation potential and a shortage of electrons giving it the ability to oxidize and sterilize. In microbial inactivation process, oxidized water damage cell membranes, create disruption in cell metabolic processes and essentially kill the cell. EOW, also a strong acid, is different to hydrochloric acid or sulfuric acid in that it is not corrosive to skin, mucous membrane, or organic material. It is easy to handle and suitable for the sanitation of the plant and decontamination of foods. Electrolyzed water has been tested and used as a disinfectant in the food industry and other applications.Electrolyzed Oxidized Water (EOW) is produced by passing a diluted salt solution through an electrolytic cell, having anode and cathode electrodes. The anode and cathode are separated by a bipolar membrane. Negatively charged ions—chloride and hydroxide in the diluted salt solution move to anode to give up electrons and become gas (O2, Cl2) and hypochlorous acid and having redox potential of +700 to +800 mV with pH 4.0. It has a strong oxidation potential and a shortage of electrons giving it the ability to oxidize and sterilize. In microbial inactivation process, oxidized water damage cell membranes, create disruption in cell metabolic processes and essentially kill the cell. EOW, also a strong acid, is different to hydrochloric acid or sulfuric acid in that it is not corrosive to skin, mucous membrane, or organic material. It is easy to handle and suitable for the sanitation of the plant and decontamination of foods. Electrolyzed water has been tested and used as a disinfectant in the food industry and other applications.

关 键 词:Electrolyzed OXIDIZED Anode DISINFECTANT FOOD MICROORGANISMS 

分 类 号:O6[理学—化学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象