作 者:Nancy L. Ford Andrew Jeklin Karen Yip Darren Yohan David W. Holdsworth Maria Drangova
机构地区:[1]Department of Oral Biological and Medical Sciences, The University of British Columbia, Vancouver, Canada [2]Department of Physics, Ryerson University, Toronto, Canada [3]Schulich School of Medicine & Dentistry, The University of Western Ontario, London, Canada
出 处:《Journal of Biomedical Science and Engineering》2014年第4期157-172,共16页生物医学工程(英文)
摘 要:Objective: To optimize scan time and X-ray dose with no loss of image quality for retrospectively gated micro-CT scans of free-breathing rats. Methods: Five free-breathing rats were scanned using a dynamic micro-CT scanner over 10 continuous gantry rotations (50 seconds and entrance dose of 0.28 Gy). The in-phase projection views were selected and reconstructed, representing peak inspiration and end expiration from all 10 rotations and progressively fewer rotations. A least error method was also used to ensure that all angular positions were filled. Image quality and reproducibility for physiological measurements were compared for the two techniques. Results: The least error approach underestimated the lung volume, air content in the lung at peak inspiration, and tidal volume. Other measurements showed no differences between the projection-sorting techniques. Conclusions: Seven gantry rotations (35 seconds and 0.2 Gy dose) proved to be the optimal protocol for both the in-phase images and the least error images.Objective: To optimize scan time and X-ray dose with no loss of image quality for retrospectively gated micro-CT scans of free-breathing rats. Methods: Five free-breathing rats were scanned using a dynamic micro-CT scanner over 10 continuous gantry rotations (50 seconds and entrance dose of 0.28 Gy). The in-phase projection views were selected and reconstructed, representing peak inspiration and end expiration from all 10 rotations and progressively fewer rotations. A least error method was also used to ensure that all angular positions were filled. Image quality and reproducibility for physiological measurements were compared for the two techniques. Results: The least error approach underestimated the lung volume, air content in the lung at peak inspiration, and tidal volume. Other measurements showed no differences between the projection-sorting techniques. Conclusions: Seven gantry rotations (35 seconds and 0.2 Gy dose) proved to be the optimal protocol for both the in-phase images and the least error images.
关 键 词:Respiratory-Gating MICRO-CT Lung Imaging FREE-BREATHING RATS TIDAL Volume
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.205