An Improved High Performance Liquid Chromatographic Method for Identification and Quantization of Polyamines as Benzoylated Derivatives  被引量:2

An Improved High Performance Liquid Chromatographic Method for Identification and Quantization of Polyamines as Benzoylated Derivatives

在线阅读下载全文

作  者:Rajat Sethi Sai Raghuveer Chava Sajid Bashir Mauro E. Castro 

机构地区:[1]不详

出  处:《American Journal of Analytical Chemistry》2011年第4期456-469,共14页美国分析化学(英文)

摘  要:A simple reversed phase HPLC method was developed for the determination of Putrescine, Cadaverine and Spermidine (a class of polyamines) in their benzoylated form from external known standards. In the optimization procedure, a number of parameters were examined: 1) Solvent used in the extraction of standard polyamines (diethyl ether versus chloroform);2) Solvent used in the elution of the polyamine (methanol versus acetonitrile);3) Mode of derivatization and extraction step(s) (derivatization and extraction performed together versus derivatization and extraction performed separately);and 4) Other instrumental parameters (such as UV detection wavelength, gradient profiles). The advantages of our method, relative to the standard Morgan method are: a) decreased chromatographic runtime, b) ease of preparation with good resolution, sensitivity, and reproducibility using a standard RP-HPLC method.A simple reversed phase HPLC method was developed for the determination of Putrescine, Cadaverine and Spermidine (a class of polyamines) in their benzoylated form from external known standards. In the optimization procedure, a number of parameters were examined: 1) Solvent used in the extraction of standard polyamines (diethyl ether versus chloroform);2) Solvent used in the elution of the polyamine (methanol versus acetonitrile);3) Mode of derivatization and extraction step(s) (derivatization and extraction performed together versus derivatization and extraction performed separately);and 4) Other instrumental parameters (such as UV detection wavelength, gradient profiles). The advantages of our method, relative to the standard Morgan method are: a) decreased chromatographic runtime, b) ease of preparation with good resolution, sensitivity, and reproducibility using a standard RP-HPLC method.

关 键 词:POLYAMINE RP-HPLC STANDARDIZATION BENZOYLATION 

分 类 号:O6[理学—化学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象