作 者:Yuwadee Boonyasit Chakorn Chinvongamorn Orawon Chailapakul Wanida Laiwattanapaisal
机构地区:[1]Department of Chemistry, Faculty of Science and Technology, Rajamangala University of Technology Thanyaburi, Pathum Thani, Thailand [2]Department of Clinical Chemistry, Faculty of Allied Health Sciences, Chulalongkorn University, Bangkok, Thailand [3]Graduate Program in Clinical Biochemistry and Molecular Medicine, Faculty of Allied Health Sciences, Chulalongkorn University, Bangkok, Thailand [4]Sensor Research Unit, Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok, Thailand
出 处:《American Journal of Analytical Chemistry》2012年第2期131-137,共7页美国分析化学(英文)
摘 要:A sequential injection analysis (SIA) system for the determination of total calcium in blood has been implemented. The assay principle is based on the arsenazo III method, in which the indicator’s complex with calcium forms a blue-purple colour. The absorbance peak height at 650 nm was proportional to the calcium content in samples. A linear range was obtained from 2.5 - 15 mg?dL–1 (r2 = 0.999), with a detection limit of 0.430 mg?dL–1 (3σ). Magnesium, glucose, hae-moglobin, and bilirubin at 123, 1,000, 50, and 0.5 mg?dL–1, respectively, were not found to interfere with the proposed system significantly (recovery 99.1% - 104.4%). The sampling frequency was 30 h–1, in which the carry-over effect was negligible (0.69%). The proposed SIA system was successfully applied to the determination of calcium from serum samples (r2 = 0.970;n = 30).A sequential injection analysis (SIA) system for the determination of total calcium in blood has been implemented. The assay principle is based on the arsenazo III method, in which the indicator’s complex with calcium forms a blue-purple colour. The absorbance peak height at 650 nm was proportional to the calcium content in samples. A linear range was obtained from 2.5 - 15 mg?dL–1 (r2 = 0.999), with a detection limit of 0.430 mg?dL–1 (3σ). Magnesium, glucose, hae-moglobin, and bilirubin at 123, 1,000, 50, and 0.5 mg?dL–1, respectively, were not found to interfere with the proposed system significantly (recovery 99.1% - 104.4%). The sampling frequency was 30 h–1, in which the carry-over effect was negligible (0.69%). The proposed SIA system was successfully applied to the determination of calcium from serum samples (r2 = 0.970;n = 30).
关 键 词:SEQUENTIAL Injection ANALYSIS System CALCIUM ARSENAZO III Green Chemistry SPECTROPHOTOMETRY Clinical ANALYSIS
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.15