Seepage Investigation on an Existing Dam Using Very Low Frequency Electromagnetic (VLF-EM) Methods: A Case Study of Shagari Earth Dam, Sokoto, North Western Nigeria  被引量:1

Seepage Investigation on an Existing Dam Using Very Low Frequency Electromagnetic (VLF-EM) Methods: A Case Study of Shagari Earth Dam, Sokoto, North Western Nigeria

在线阅读下载全文

作  者:U. Z. Magawata[1] D. S. Bonde[1] B. U. Abdullahi[1] Basiru Qudus[1] M. N. Yahaya[1] 

出  处:《International Journal of Geosciences》2020年第2期25-36,共12页地球科学国际期刊(英文)

摘  要:Very low frequency (VLF-EM) was used to assess variations in overburden composition, bedrock lithology and the hidden Sedimentary structures within the foundation of Shagari Dam of the sedimentary basin of Northwestern Nigeria. Four VLF-electromagnetic (EM) traverses were occupied at 10 m in-tervals. The VLF normal and filtered real component irregularities identify major geological interfaces suspected to be faults/fractured zones. The points of crossover between the real and imaginary components delineate the fractured zones, which were identified as areas of possible seepage (sloughing and piping). The fractured zones are suspected to be present at all traverses. In total, 38 fractured zones were identified along the dam embankment and canal site, while 17 major fractures occurrence dippers along the Traverses at a point, Traverse 1 (F3, F4, F5, F7, F10, F11), Traverse 2 (F12, F13, F21, F22), Traverse 3 (F23, F24, F29) and Traverse 4 (F32, F33, F34, F38), and coincide with cross over point at 4 traverses. These seepage zones cause heterogeneity in the sub-surface structure that could be prime to dam failure which in turn leads to the flooding, decreases in irrigations activities of the peoples leaving around the dam and loss of several hundreds of life when care not taken. The result of the study suggests that VLF is suitable for observing seepages in embankment dams.Very low frequency (VLF-EM) was used to assess variations in overburden composition, bedrock lithology and the hidden Sedimentary structures within the foundation of Shagari Dam of the sedimentary basin of Northwestern Nigeria. Four VLF-electromagnetic (EM) traverses were occupied at 10 m in-tervals. The VLF normal and filtered real component irregularities identify major geological interfaces suspected to be faults/fractured zones. The points of crossover between the real and imaginary components delineate the fractured zones, which were identified as areas of possible seepage (sloughing and piping). The fractured zones are suspected to be present at all traverses. In total, 38 fractured zones were identified along the dam embankment and canal site, while 17 major fractures occurrence dippers along the Traverses at a point, Traverse 1 (F3, F4, F5, F7, F10, F11), Traverse 2 (F12, F13, F21, F22), Traverse 3 (F23, F24, F29) and Traverse 4 (F32, F33, F34, F38), and coincide with cross over point at 4 traverses. These seepage zones cause heterogeneity in the sub-surface structure that could be prime to dam failure which in turn leads to the flooding, decreases in irrigations activities of the peoples leaving around the dam and loss of several hundreds of life when care not taken. The result of the study suggests that VLF is suitable for observing seepages in embankment dams.

关 键 词:OVERBURDEN Interfaces OCCURRENCE HETEROGENEITY EMBANKMENT 

分 类 号:U21[交通运输工程—道路与铁道工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象