Project supported by the National Natural Science Foundation of China(Grant Nos.11305074,11135002,11804112,and 11275083);the Key Program of the Education Department Outstanding Youth Foundation of Anhui Province,China(Grant No.gxyqZD2017080);the Natural Science Foundation of Anhui Province,China(Grant No.KJHS2015B09);the Open Fund of Anhui Ley Laboratory for Condensed Matter Physics under Extreme Conditions and CAS Key Laboratory of Microscale Magnetic Resonance(Grant No.KLMMR201804);the Fund of Scientific Research Platform of Huangshan University
We carried out a proof-of-principle demonstration of the reconstruction of a static vector magnetic field involving adjacent three nitrogen-vacancy(NV) sensors with corresponding different NV symmetry axes in a bulk d...
Protect supported by the National Natural Science Foundation of China(Grant Nos.11305074,11135002,and 11275083);the Key Program of the Education Department Outstanding Youth Foundation of Anhui Province,China(Grant No.gxyq ZD2017080);the Natural Science Foundation of Anhui Province,China(Grant No.KJHS2015B09)
We suggest an experimental scheme that a single nitrogen-vacancy(NV) center coupled to a nearest neighbor ^13C nucleus as a sensor in diamond can be used to detect a static vector magnetic field. By means of optical...
Project supported by the National Natural Science Foundation of China(Grant Nos.11305074,11135002,and 11275083);the Key Program of the Education Department Outstanding Youth Foundation of Anhui Province,China(Grant No.gxyq ZD2017080);the Education Department Natural Science Foundation of Anhui Province,China(Grant No.KJHS2015B09)
We perform a proof-of-principle experiment that uses a single negatively charged nitrogen–vacancy(NV) color center with a nearest neighbor ^13C nuclear spin in diamond to detect the strength and direction(includin...
supported by the National Natural Science Foundation of China(NSFC)(Nos.11404153,11135002,11604119,and 11405077);the Fundamental Research Funds for the Central Universities of China(No.lzujbky-2017-14)
We investigate the nonadiabatic spectral redshift of high-order harmonic of He driven by two time-delayed orthogonally polarized laser fields. It is found that the nonadiabatic spectral redshift can be observed by pro...
Project supported by the National Natural Science Foundation of China(Grant Nos.11404153,11135002,11475076,and 11405077);the Fundamental Research Funds for the Central Universities of China(Grants Nos.lzujbky-2016-29,lzujbky-2016-31,and lzujbky-2016-209)
We calculated the harmonic spectra generated from the asymmetric molecules of HD^+ and HeH^2+. It is found that HD+produces only odd harmonics, while HeH^2+produces both odd and even harmonics. Further analysis re...
Project supported by the National Natural Science Foundation of China(Grant Nos.11404153,11135002,11475076,and 11405077);the Fundamental Research Funds for the Central Universities of China(Grants Nos.lzujbky-2016-29,lzujbky-2016-31,and lzujbky-2016-209)
The wavelength dependence of electron localization of H2^+ and its isotopomers in the ultraviolet pump-probe scheme is investigated by numerically solving the time-dependent Schrodinger equation. By combining with a ...
supported by the National Natural Science Foundation of China(Nos.11504148 and 11135002);the Fundamental Research Funds for the Central Universities(Nos.lzujbky-2015-269 and lzujbky-2015-242)
From a classical dynamic simulation,we find the kinetic energy of the electrons generated during laser plasma generation depends on the laser polarization and intensity.The electron kinetic energy reaches its maximum ...
Supported by National Natural Science Foundation of China(11135002,11275235,11405077,11575073)
Gas electron multiplier (GEM) detectors have been used in cosmic muon scattering tomography and neutron imaging over the last decade. In this work, a triple GEM device with an effective readout area of 10 cm × 10 c...
the National Natural Science Foundation of China(Grant Nos.11504148 and 11135002)
Dear Editors,Energy exchange between two filamentary pulses was demonstrated in several experiments [ 1-4], and the energy- transfer direction depends on the time delay between filamen- tary pulses, the initial chirp,...