the National Natural Science Foundation of China(Nos.71231001,71301009 and71420107023);Ministry of Education Doctor of Philosophy Supervisor Fund of China(No.20120006110025);the Fundamental Research Funds for the Central Universities of China(No.Fl TR-TP-15-031A3)
The inspection activities are often carried out to detect possible indication of failures in plant systems.This paper considers a single unit system subject to two types of failures, where one failure mode is the trad...
the National Natural Science Foundation of China(Nos.11426084,11001005,71231001,71301009 and 71420107023);the China Postdoctoral Science Foundation Funded Project(No.2013M530531);the Natural Science Foundation of Hebei Province(No.A2014208133);the Foundation of Hebei Education Department(No.QN2014132);the Ministry of Education Doctor of Philosophy Supervisor Fund(No.20120006110025)
In this paper, we consider the replacement of a single unit with catastrophic failure mode. Besides replaced at a preset time, the unit is also replaced at failure time or if it encounters a production wait and its ag...
National Natural Science Foundations of China(Nos.71231001,11001005,71301009);China Postdoctoral Science Foundation(No.2013M530531);the Fundamental Research Funds for the Central Universities of China(Nos.FRF-M P-13-009A,FRF-TP-13-026A);the MOE PhD Supervisor Fund of China(No.20120006110025)
A series-parallel system was proposed with common bus performance sharing in which the performance and failure rate of the element depended on the load it was carrying. In such a system,the surplus performance of a su...