Solid-Contact Ion-Selective Electrodes Based on Graphite Paste for Potentiometric Nitrate and Ammonium Determinations被引量:1
《American Journal of Analytical Chemistry》2018年第12期591-601,共11页Johannes Schwarz Kathrin Trommer Michael Mertig 
Robust and easy-to-handle solid-contact ion-selective electrodes (SC-ISEs) based on graphite paste have been developed for the potentiometric detection of NO-3 and NH+4 in environmental samples. Polypyrrole (PPy) has ...
关键词:Solid-Contact Electrode GRAPHITE PASTE ALL-SOLID-STATE Configuration Ion-Complexing Compound Environmental Samples 
Shift in pKa of 1,10-Phenanthroline in TBAB and PEG-400 Micellar Media: A Potentiometric Study
《American Journal of Analytical Chemistry》2018年第9期397-405,共9页Atnafu Guadie Assefa Rongali Srinivasu Pulipaka Shyamala Gollapalli Nageswara Rao 
The acid-base equilibrium of 1,10-phenanthroline (1,10-phen) in the presence of polyethylene glycol 400 (PEG-400, non-ionic) and tetrabutylammonium bromide (TBAB, ionic) micellar media has been studied by Calvin-Wilso...
关键词:PROTONATION Equilibria 1 10-PHENANTHROLINE MINIQUAD75 PEG-400 TBAB Micelles 
All-Solid-State Screen-Printed Sensors for Potentiometric Calcium(II) Determinations in Environmental Samples
《American Journal of Analytical Chemistry》2018年第3期113-123,共11页Johannes Schwarz Kathrin Trommer Frank Gerlach Michael Mertig 
This paper describes preparation, characterization and electrochemical performance of novel planar miniaturized all-solid-state (ASS) screen-printed potentiometric sensors for the detection of Ca2+ ions in environment...
关键词:ALL-SOLID-STATE Sensor Ca2+-Selective Electrode POTENTIOMETRIC TITRATION Environmental SAMPLES 
Potentiometric Study of Dissociation Constants of Dihydroxybenzoic Acids at Reduced Ionic Strengths and Temperatures
《American Journal of Analytical Chemistry》2017年第2期142-150,共9页Jorgen Rosenqvist Caroline M.Jonsson 
The Swedish Foundation for Strategic Environmental Research(Mistra)for financial support through the Mistra Environmental Nanosafety Program.
The dissociation behavior of two dihydroxybenzoic acid isomers, 2,3-DHBA and 3,4-DHBA, at 281 K and 293 K was determined by potentiometric titrations in 0.01 M NaCl and 0.03 M NaCl. Results showed that the dissociatio...
关键词:2 3-Dihydroxybenzoic Acid 3 4-Dihydroxybenzoic Acid Dissociation Constant PKA Temperature Ionic Strength Surface Water 
A Theoretical Model of pH-Based Potentiometric Biosensor Based on Immobilized Enzyme Membrane
《American Journal of Analytical Chemistry》2016年第4期363-377,共15页Jeganathan Saranya Lakshmanan Rajendran Mariappan Uma Maheswari 
A theoretical model for the non steady-state response of a pH-based potentiometric biosensor immobilizing organophosphorus hydrolase (OPH) is discussed. The model is based on a system of five coupled nonlinear reactio...
关键词:Mathematical Modeling REACTION-DIFFUSION pH-Based Potentiometric Biosensor Asymptotic Methods New Homotopy Perturbation Method 
Sequential Injection Analysis of Ampicillin in Pharmaceuticals by Using Potentiometric Detectors Based on PVC and Sol-Gel Membranes
《American Journal of Analytical Chemistry》2011年第4期491-499,共9页Nestor Zarate Alberto N.Araujo M.Conceicao B.S.M.Montenegro Ricardo Perez-Olmos 
supported by the University of the Basque Country(Spain)through Project UPV 171.363-E-15923/2004;this University for the Ph.D.Grant 98/13828/01.
This work describes the construction and the evaluation of the general performance of new ampicilli-nate-selective electrodes based on manganese (III) tetraphenylporphyrin [Mn(III) TPP-Cl] as ionophore, incorporated i...
关键词:AMPICILLIN SIA Potentiometric Detection Pharmaceutical Formulations 