Most of existing methods for the safety assessment of the primary cooling loop of nuclear reactors in conditions of reactor coolant pump(RCP)failure(rotor seizure accident)essentially rely on the combination of one-di...
National Science and Technology Major Project of China(No.2017-II 0006-0020);National Key Research and Development Project of China(2016YFB0200901);National Natural Science Foundation of China(51776154)。
Accurate and efficient prediction of the aerodynamic performance and flow details of axial-flow com-pressors is of great engineering application value for the aerodynamic design and flow control of axial-flow compres-...
This work is financially supported by the National Key Research and Development Project of China(Grant No.2016YFB0200901);National Natural Science Foundation of China(Grant No.51776154);National Science and Technology Major Project of China(Grant No.2017-II-0006-0020);Shaanxi Key Research and Development Project(Grant No.2018KWZ-01).
Existing aerodynamic design systems for multi-stage axial-flow compressor suffer from several limitations,such as experience dependent models and time costly simulations.Few attempts,however,have been devoted to the r...
China Nature Science Funds(51279173);“The 12th Five-year”Key Project of National Science and Technology Support Plan(2015BAD20B01);Jiangsu Water Conservancy Science and Technology Project(2017031)
In order to study the mechanism of the vortex generation at the bottom of the pump sump below the flare tube,twenty pressure pulsation monitoring points were arranged at the bottom of the pump sump below the flare tub...
Strategic Leading Project of Shanghai Municipal Science Committee(16DZ1121202)
Airfoil is the element of fan blade design. It is strongly anticipated to design a fan of ave- raged high performance over a wide operation range. Multi-point optimization design of airfoil for axial flow fan was prop...
Supported by the National Natural Science Foundation of China(No.51574161);the Education Science Project of Young and Middle-aged Teachers of Universities in Fujian Province(No.JZ160396)
To study the effect of guide vane outlet angle on pump performance and impeller radial force in an axial-flow heart pump, guide vane outlet angle/34 is considered to be 20°, 15°, 10°, 5° and 3° respectively. Base...
Two different flow channel configurations on thermal resistances associated with the behavior of cooling of power device were studied in this paper. ANSYS Icepak 14.0 has been adopted as a numerical simulation tool. T...
A one-dimensional fluid model has been used to describe the effect of radio frequency (RF) on the characteristics of carbon dioxide (CO2), nitrogen (N2) and helium (He) mixture discharge at 120 mbar in fast-ax...
This study aimed to explore the characteristics of perioperative nursing of experimental goats using self-made axial-flow blood pump implantation and provided theoretical nursing knowledge and practice-based evidence ...