Comparison of the Retinomax hand-held autorefractor versus table-top autorefractor and retinoscopy  被引量:4

Comparison of the Retinomax hand-held autorefractor versus table-top autorefractor and retinoscopy

在线阅读下载全文

作  者:Ibrahim Tuncer Mehmet Ozgur Zengin Eyyup Karahan 

机构地区:[1]Alfagoz Eye Center [2]Department of Ophthalmology, Izmir University Faculty of Medicine

出  处:《International Journal of Ophthalmology(English edition)》2014年第3期491-495,共5页国际眼科杂志(英文版)

摘  要:AIM:To compare noncycloplegic and cycloplegic results of Retinomax measurements with findings achieved after cycloplegia using table-top autorefractor and retinoscopy.METHODS:The study included 127 patients(mean age96.7mo,range 21 to 221).Retinomax(Rmax)(Nikon Inc.,Japan)was used to obtain noncycloplegic refraction.Under cycloplegia,refraction was measured with Rmax,table-top autorefractor(TTR)(Nikon NRK 8000,Inc.,Japan)and retinoscopy.The values of sphere,spherical equivalent,cylinder and axis of cylinder were recorded for Rmax,TTR and retinoscopy in each eye.All results were analyzed statistically.RESULTS:The mean spheric values(SV),spherical equivalent values(SEV)and cylindrical values(CV)of the noncycloplegic Rmax(SV:0.64 D,SEV:0.65 D and CV:0.03 D,respectively)were found to be significantly lower than cycloplegic TTR(1.43 D,1.38 D and 0.3 D;P=0.012,P=0.011 and P=0.04,respectively)and retinoscopy(1.34 D,1.45 D and 0.23 D;P=0.04,P=0.002 and P=0.045,respectively).Mean cycloplegic SV,SEV,CV were not significantly different between Rmax and TTR,Rmax and retinoscopy,TTR and retinoscopy.Cycloplegic or noncycloplegic axis values were not different between any method.CONCLUSION:Rmax may be used successfully as a screening tool but may not be accurate enough for actual spectacle prescription.Cycloplegic Rmax measurements may be able to identify refractive error in children because of approximate results to retinoscopy.AIM:To compare noncycloplegic and cycloplegic results of Retinomax measurements with findings achieved after cycloplegia using table-top autorefractor and retinoscopy.METHODS:The study included 127 patients(mean age96.7mo,range 21 to 221).Retinomax(Rmax)(Nikon Inc.,Japan)was used to obtain noncycloplegic refraction.Under cycloplegia,refraction was measured with Rmax,table-top autorefractor(TTR)(Nikon NRK 8000,Inc.,Japan)and retinoscopy.The values of sphere,spherical equivalent,cylinder and axis of cylinder were recorded for Rmax,TTR and retinoscopy in each eye.All results were analyzed statistically.RESULTS:The mean spheric values(SV),spherical equivalent values(SEV)and cylindrical values(CV)of the noncycloplegic Rmax(SV:0.64 D,SEV:0.65 D and CV:0.03 D,respectively)were found to be significantly lower than cycloplegic TTR(1.43 D,1.38 D and 0.3 D;P=0.012,P=0.011 and P=0.04,respectively)and retinoscopy(1.34 D,1.45 D and 0.23 D;P=0.04,P=0.002 and P=0.045,respectively).Mean cycloplegic SV,SEV,CV were not significantly different between Rmax and TTR,Rmax and retinoscopy,TTR and retinoscopy.Cycloplegic or noncycloplegic axis values were not different between any method.CONCLUSION:Rmax may be used successfully as a screening tool but may not be accurate enough for actual spectacle prescription.Cycloplegic Rmax measurements may be able to identify refractive error in children because of approximate results to retinoscopy.

关 键 词:AUTOREFRACTOR hand-held refractors RETINOSCOPY Retinomax 

分 类 号:R778.2[医药卫生—眼科]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象