检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]清华大学自动化系,北京100084
出 处:《工业加热》2006年第2期13-15,共3页Industrial Heating
摘 要:采用递推的带遗忘因子的最小二乘方法,以现场测得的熔炼电流为输入,实际熔化率为模型输出,对电渣重熔过程进行辨识,得到了精度较高的系统时变模型,并证明了模型的可靠性。通过与电渣炉机理建模的结果进行对比,证明了辨识模型的优越性。基于此模型建立的先进控制方法已经成功运用于邢台冶金轧辊集团电渣炉车间,效果良好。A high precision time-various model is obtained by system identification of electro-slag remelting process. We use least squares method with forgetting factor for system identification, setting the melting current gained at spot as input, and actual melt-rate as output. The dependability of the model is also validated. After a compare with the model established by electro-slag remelting mechanism, the model gained by identification is proved to be better and more convenience for use. The advanced control method based on this model is successfully used in electro-slag remelting plant of Xingtai Metallurgy and Roller Group and achieved a good effect.
分 类 号:TM924.43[电气工程—电力电子与电力传动] TP273.1[自动化与计算机技术—检测技术与自动化装置]
正在载入数据...
正在载入数据...
正在载入数据...