检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]哈尔滨工业大学
出 处:《宇航计测技术》1999年第6期12-16,共5页Journal of Astronautic Metrology and Measurement
摘 要:多关节坐标测量机末端测头的位置准确度主要受各杆件结构参数误差的影响,为提高多关节坐标测量机的测量准确度,必须对各杆件的结构参数进行校准。首先应用DH 分析方法,建立了多关节坐标测量机的运动学模型,然后提出了一种简单、快速的单点 多姿态校准方法,运用全微分、最小二乘法和迭代算法等数学方法,建立了校准模型。实验表明,该校准方法适合于多关节坐标测量机结构参数真值的获得,并可极大地提高测量机的位置准确度。The main factor that affect measuring accuracy of multi joint CMM is structure parameter errors of links. In order to improve it's accuracy, it is necessary to calibrate the structure parameters of links. The kinematics model of multi joint CMM is constructed by using D H method. A simple and rapid single point multi posture calibration method is proposed. This calibration model is founded by applying total differential, least square and iterative algorithm. It is demonstrated by experiment that this calibration is suitable for obtaining true structure parameters of links and the position accuracy of multi joint CMM can be improved greatly.
分 类 号:TH721[机械工程—仪器科学与技术] TG839[机械工程—精密仪器及机械]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.68