检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:乙小娟[1] 王玥[1] 张慧[1] 夏拥军[1] 李磊[2] 赵鸿雁[2] 郭莹莹[2]
机构地区:[1]张家港出入境检验检疫局,江苏张家港215600 [2]南京医科大学公共卫生学院,江苏南京210029
出 处:《食品工业科技》2012年第6期99-101,共3页Science and Technology of Food Industry
基 金:江苏检验检疫局项目(2009KJ34)
摘 要:采用静态顶空技术和气相色谱质谱仪(GC-MS)联用,检测了进出口油脂中苯、甲苯和二甲苯等苯系物的污染。探讨了色谱柱、恒温温度、平衡时间对测定结果的影响。结果表明,采用HP-5色谱柱,样品恒温温度为90℃,平衡时间为40min时,目标化合物测定效果好。方法检出限小于0.04mg/kg,添加回收率在89.4%(邻二甲苯)~112.5%(甲苯)之间。相对标准偏差(RSD)小于12.4%。该法具有操作简单、能够准确定性、灵敏度较高的特点。Benzene, toluene, p-xylene and o-xylene in imports and exports oils and fats were analyzed by headspace GC- MS.The effects of chromatographic column, bath temperature and equilibrium time were investigated.The results showed that the optimal conditions of determination were HP-5 chromatographic column, bath temperature 90~C, equilibrium time 40min.The detection limit, recovery and RSD were less than 0.04mg/kg, 89.4%~]12.5% and less than 12.4% .The method was simple,accurate and highly sensitive.
关 键 词:静态顶空气相色谱质谱法 苯 甲苯 二甲苯 油脂
分 类 号:TS207.3[轻工技术与工程—食品科学]