检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:邓旭旗[1] 钟志光[2] 刘崇华[2] 贺柏龄[2] 孔聘颜[3] 钟广涛[3] 戚穗坚[3] 彭松[3]
机构地区:[1]中华人民共和国东莞出入境检验检疫局,广东省东莞市523071 [2]中华人民共和国广州出入境检验检疫局,广州市510623 [3]中山大学,广州市510275
出 处:《光谱实验室》2002年第1期60-64,共5页Chinese Journal of Spectroscopy Laboratory
摘 要:采用 P50 7萃淋树脂预富集分离技术 ,用 ICP- AES法测定猪肝、猪肉中痕量稀土元素 L a、Ce、Pr、Nd、Sm、Y的含量 ;本法排除了基体中 Ca、P、Fe的干扰 ,检出限为 0 .33— 0 .74 ng/g(鲜样 ) ,回收率为 84 .8%— 10 9.1% ,精密度为 4 .9%— 11%Using preconcentration\|seperation technique with P 507 \|extraction chromatograph resin,an inductively coupled plasma atomic emission spectrometry method for determination of ultratrace rare earth elements in the pig's liver and pork has been developed.La,Ce,Pr,Nd,Sm,Y in the samples were detected without the interference of Ca,Fe & P.The detection limits of the method were in the range of 0.33 %_0.74ng/g.The recovery rates and precision of the method are in the range of 84.8 %_109.1% and 4.9%_11%,respectively.