摘  要:利用吸附法将青霉素G抗体固定于纳米金修饰的玻碳电极表面,制备用于检测青霉素G的电化学免疫传感器,建立高度灵敏的一步直接电化学免疫法.纳米金的强吸附和导电作用,提高了青霉素G抗体的固定量和电化学灵敏度.在优化条件下,该传感器的响应电流与青霉素质量浓度的对数在0.04~40.00 ng/mL范围内呈良好的线性关系,相关系数为0.988 4,检测限为2.49 ng/mL,该法成功的实现了对牛奶中青霉素G的检测.An amperometric immunosensor was fabricated by co-immobilizing penicillin G polyclonal antibody (Ab*) on the surface of a gold nanoparticle modified glassy carbon electrode through electrostatic adsorption.A highly sensitive one-step direct electrochemical immunoassay was established due to the strong adsorption and conductive capacity of gold nanoparticles,thus raising the amount of fixed penicillin G antibody and electrochemical sensitivity.Under optimized conditions,the current response of the sensor showed a good linear relationship with logarithmic penicillin concentration in the range of 0.04-40.00 ng/mL with a correlation coefficient of 0.988 4 and the detection limit was 2.49 ng/mL.The method was able to detect penicillin in milk successfully.