制药用水微生物限度检查方法比较  被引量:5

Comparison of Microbial Limit Test Methods for Pharmaceutical Water

在线阅读下载全文

作  者:张光华[1] 王似锦[1] 高春[1] 蔡春燕[1] 

机构地区:[1]北京市药品检验所,北京100035

出  处:《中国医药工业杂志》2015年第12期1330-1333,共4页Chinese Journal of Pharmaceuticals

摘  要:采用美国药典37版(USP 37)和中国药典2010年版(Ch P 2010)制药用水的微生物检查法检测北京市制药企业的制药用水。结果显示,USP 37收载的R2A琼脂培养基平板上可生长的菌落种类更多,该培养基更适合水中污染微生物的生长。USP 37中制药用水微生物检查方法更科学合理。The test methods for microbial limit recorded in USP 37 and ChP 2010 were conducted and compared for the examination of pharmaceutical water used in Beijing pharmaceutical enterprises. The results showed that there were more kinds of colony form unit grown on R2A agar medium plate, which was recorded in USP 37. R2A agar medium was more suitable for the growth of microbes in polluted water, and the test method recorded in USP 37 for the measurement of microbes in pharmaceutical water was proved to be more scientific and reasonable.

关 键 词:制药用水 微生物 限度检查 

分 类 号:Q93[生物学—微生物学]

 