检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:魏雪缘 沈伟健[2] 余可垚[2] 张建[2] 陆慧媛[2] 吴斌[2] 沈崇钰[2] 赵增运[2] 柳菡[2] 邓晓军[3] 王岁楼[1]
机构地区:[1]中国药科大学药学院,江苏南京210009 [2]江苏出入境检验检疫局食品实验室,江苏南京210001 [3]上海出入境检验检疫局动植物与食品检验检疫技术中心,上海200135
出 处:《色谱》2016年第4期429-435,共7页Chinese Journal of Chromatography
基 金:国家质检总局科技计划项目(2015IK141);江苏省"333工程"项目(BRA2014330);上海长三角科技合作项目(15395810100)~~
摘 要:分别采用电子轰击(EI)和正化学电离(PCI)两种离子源技术建立了气相色谱-质谱联用法(GC-MS)同时测定橄榄油中3,5-菜甾二烯、3,5,22-豆甾三烯和3,5-豆甾二烯3种甾醇烯含量的方法,并对这两种方法进行了比较。样品经石油醚溶解,硅胶柱净化后,分别采用GC-EI/MS和GC-PCI/MS分时段选择离子监测模式进行测定,以3,5-胆甾二烯为内标进行定量。结果表明,两种方法的线性、准确度、精密度、灵敏度均较好。3,5-菜甾二烯、3,5,22-豆甾三烯和3,5-豆甾二烯分别在0.024~0.48、0.02~0.50和0.03~0.75 mg/L浓度范围内线性关系良好(r〉0.999)。在3个加标水平下,GC-EI/MS和GC-PCI/MS的平均回收率分别为88.7%~99.5%、87.1%~109.2%,两种检测方法的相对标准偏差(RSD,n=6)均不超过8.3%。定量限(S/N=10)分别为0.03 mg/kg(EI),0.03~0.10 mg/kg(PCI)。通过对两种方法的比较研究发现,EI能提供更多碎片离子和结构信息,而PCI中则主要为准分子离子及反应气加合离子。应用于样品中甾醇烯的测定时,PCI的选择性和抗干扰能力明显优于EI。两种方法可相互补充和替代应用于日常检测中。The gas chromatography-mass spectrometric(GC-MS)method with two different ionization techniques,electron impact(EI)and positive chemical ionization(PCI),have been developed for the simultaneous determination of three sterenes in olive oil. The olive oil sample was dissolved in petroleum ether,followed by cleanup on a silica gel column and finally analyzed by GC-EI/MS and GC-PCI/MS in selected ion monitoring mode. The quantitation was performed by internal standard calibration with cholesta-3,5-diene as internal standard. These two methods were compared in terms of linearity,accuracy,precision and sensitivity. Good linearities were obtained with correlation coefficients(r)higher than 0. 999 for campesta-3,5-diene in the range of 0. 024 to 0. 48 mg/L,stigmasta-3,5,22-triene in the range of 0. 02 to 0. 50 mg/L andstigmasta-3,5-diene in the range of 0. 03 to 0. 75 mg/L. The accuracy test was carried out at three spiked levels in extra virgin olive oil. The average recoveries ranged from 88. 7% to 99. 5%(EI)and 87. 1% to 109. 2%(PCI),with relative standard deviations(RSDs,n = 6)not higher than 8. 3%. Limits of quantification(LOQs,S/N = 10)were 0. 03 mg/kg(EI)and 0. 03- 0. 10 mg/kg(PCI). Comparative analysis showed a large number of fragment ions could be obtained in EI mode while quasi-molecular ions or other adduct molecular ions were the most abundant ion formed in the PCI mode. Besides,PCI has a better selectivity than EI when applied to real samples. In conclusion,these two ionization techniques are complementary and alternative in the routine analysis of sterenes in olive oil.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.244